Before installing a burglar alarm try to put yourself in the mind of a burglar and second-guess what they might do. Do not forget the more simple common sense physical security measures like locking doors, putting locks on windows, taking keys out of locked doors, installing 5 lever locks, bolts and grills. Keep car keys out of sight, handbags and wallets off of the chair by the window, etc.
4 out of 5 burglaries occur when there is know one at home. Do not advertise the fact that you are away. Remember to cancel the milk, get a neighbour to pick the mail up for you or for a small sum the Post Office can hold the mail for you while you are away. Curtains drawn in the daytime can be an indication that the occupants are away. Try to mow the lawn just before you leave or better still get a neighbour to run over it for you while you are away. If you give your house keys to a trusted neighbour ask them not to put your house number on them in case they fall into the wrong hands. Do not cancel the papers in front of a shop full of people and do not have your address on your cases during your outbound journey. The fewer people that know you are away and know your address the safer your property will be. A good investment is one of the plug in security switches that switch on with a timer. Plugging a table lamp into one of these will make your house look occupied during the evening hours.
Try to work with your neighbours to look after empty property while the occupants are on holiday. Try to check the windows and doors frequently and don’t hesitate to telephone the police if anything untoward is spotted.
Take a look at your garden, are your garden tools locked away and are their any items left outside that might aid the burglar in gaining entry into your house. If you own a set of ladders either lock them inside the garage or shed, or padlock them to a secure bracket outside.
There is a wide range of security information available on the web. Below are some links to potentially useful sources of information.
The Crime Prevention Organisation - http://www.crime-prevention.org.uk/
Crime Stoppers - http://www.crimestoppers-uk.org/
Neighbourhood Watch - http://www.nwatch.org.uk/
Looking for a User Guide or how to get your burglar alarm code back? Click here
We are unable to take responsibility for the accuracy of any information provided in any of the web sites mentioned above.
Q. Hi alert , do you sell the texecom 3E bell/box 109 db backplate on its own, and the cost please, kind regards Wilf
Good Morning Wilf
if you can contact us at Support@support.alertelectrical.com then we can quote this for you
Many Thanks
Nathan Swann
Q. Hi have u sent the spring out yet as I have here nothing for anyone and not received the spring yet
Good Morning Ben
if you could contact support@support.alertelectrical.com then we can advise on this for you
Many Thanks
Nathan Swann
Q. I have a aritech cs350 will a texecom veritas 8 compact alarm pannel fit.
Good Morning John
Unfortunately i have no information on the Airtech CS350 so i would be unable to advise on this
Many thanks
Nathan Swann
Q. Hi Am I correct in presuming the scantronic 9651 panel at £73. 92 comes complete with a 9943 keypad and proximity tag. Thanks Kevin
Good Morning Kevin
If you order the 9651EN-43 Unit then this will have the 9943 keypad and the extra Tags are the PROXTAGPK5
Many Thanks
Nathan Swann
Q. I have a faulty duel tech esp detector which i purchased on 20/03/2012 w2012032on and would like it replaced cheers tony.with my new order dated 24/09/2012
Good Morning Anthony
if you could email your request to support@support.alertelectrical.com we can advise further on this for you
Many Thanks
Nathan Swann
Q. I have a veritasr8 burglar alarm which 2 days ago was triggered .Ihave been able to silence the alarm but for some reason the blue outside light continues to flash. I have tried to eliminate this by resetting the alarm but with no success. Please advise. Many thanks.
Good Afternoon Herbert,
Thank you for contacting Alert Electrical,
If you contact Texecom on the following number they should be able to advise you : TEXECOM LTD: 01706 220460
Kind Regards
Emma Stevenson
Q. ADE Gen4 Pro Kit with LCD Remote Keypad do I need an internal sounder with this kit?
Good Afternoon Dave
there is a sounder on both the panel and keypad and so i would say an additional speaker would be un necessary for this application
Many Thanks
Nathan Swann
Q. Hi, I hope you can help me. I have a burglar alarm with a Veritas remote keypad. Does a "user manual" exist for this product ? I can find installation manuals all over the internet but the company who make this don't seem to produce a user manual for the poor idiot who is stupid enough to have one installed. Any ideas ? Thanks, Nick Murray
Good Afternoon Nick
i have emailed a copy of the Manual to nicholaskmurray@gmail.com for you
Many Thanks
Nathan Swann
Q. I have an accenta g4 alarm 8SP411A, recently if the power has been turned off at the supply board, the alarm has activated and date and time changed to start up time - 00:00. All other information is still held ie. zones/programs. Does this mean I might have a problem with the panel and need to purchase a new alarm panel (I have turned the power off to the alarm and the battery kicks in okay and runs for hours, so I don't think it's battery issue) Wondered if you have come across this before so grateful for advice. Thanks Mark
Good Afternoon Mark
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Emma stevenson
Q. Do you sell a Scantronic 9651EN43 KIT with proximity tags and all the parts for a burglur Alarm system (similar to your 9651EN41 Kit). If so at what price?
Good Afternoon Brendan,
If you would like to make up your own kit- You can do this online.
Kind Regards
Emma Stevenson
Q. I own an equestrian business. There are three buildings in close proximity to each other, all with mains electricity. I can connect all three buildings with alarm cable discreatley. I would prefer each door to each building to have contacts, with a control panel in the main building, and an outside bell/siren, People are always on the premises and the house is no more than 30 metres from where the alarm would sound. can you provide me with a system or parts that would cover the above requirements with instructions please
Thank you for contacting Alert Electrical Support. If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Thank you for your enquiry.
Q. How much is a mounting bracket for a Texecom PIR.
Good Morning Andrew,
Please can you tell me which Texecom PIR you have? then i can give you advise on which mounting bracket you will need as there is so many to choose from.
Kind Regards
Emma Stevenson
Q. Hi, Is the I-ON 16 a hybrid alarm system? We have a wired system at present and want to replace some of it with wireless and keep some wired PIRS. If not, what keypad do I need to buy with the I-ON 30 alarm - it is a little confusing since it shows a keypad but states it is only the panel included?
Good Afternoon Jill,
The ION-16 is a Keypad and Panel - it can be wireless and wired,
The ION-30 is just the panel, you would need to buy the keypad aswell as its sold separately
Hope this Helps
Kind Regards
Emma Stevenson
Q. I did google search online for an alarm keypad. your company came up with best price with free dilevery. but once on site. its not free. is this false advertiseing
Good Morning Bryan,
Unfortunately we do not do free shipping,
Google have put that on them self’s- we did not - We have never done free shipping.
My apologies for the misleading advertisement.
Q. Please can you do the price promise on a few items Excel Keypad - http://www.securitywarehouse.co.uk/catalog/texecom-veritas-excel-r8-lcd-rkp-p-341.html 3.4Ah Battery - http://www.securitywarehouse.co.uk/catalog/enersys-12v-34-ah-battery-p-1870.html ADE Honeywell Activ8 PIR - http://www.securitywarehouse.co.uk/catalog/honeywell-activ8-pir-single-channel-18m-quad-element-pet-pir-p-2057.html
Good Morning Michael
if you could email this to support@support.alertelectrical.com we can advise on this for you
Many Thanks
Nathan Swann
Q. Does ade bellbox the one for #16.88 include the nicad
Good Afternoon Patrick,
Yes the ade-bellbox-the-one-for-£16.88 does include the Nicad.
Kind Regards
Emma Stevenson
Q. Is it possible to order over the phone
Good Morning Dave,
Unfortuenty we do not take order over the phone and all orders have to be placed online, this is due to security reason
Kind Regards
Emma Stevenson
Q. Why can I not track my package W20120620N18
Good Morning Mr Thorpe
Your DHL Waybill number is 6291255250
i have this down as received in a depot on Malaga and delivery should be in the next few days
Many Thanks
Q. Will the Scantronic 9448eur90 control panel replace the 9452 panel & is it mains plus battery back up the same as the 9452 thank you ?
Good Morning Dennis
Looking at this i would suggest that the Scantronic 9651EN-41 would be a more suitable panel for your needs
Many Thanks
Nathan Swann
Q. Hi there i have a veritas r8 alarm i want to know how to change entry delay time
Good Morning Adam
Unfortunately this is not something we would know
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Many Thanks
Nathan Swann
Q. Hello .i purchased a ag6 intellense bell box from you , could you tell me if any visual indicator light should be on the box either when the alarm is set or unset thankyou sammy
Good Morning Sammy
Unfortunately this is not something i would have information on
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Many Thanks
Nathan Swann
Q. I am looking for a large capacity back up battery for my veretas R8 control panel. I am not sure if the 7Ah one on your site will fit as it seems to be quite a bit bigger than the small one in there at the moment? Many thanks.
Good Morning Robert
unfortunately a 7amp battery would not be suitable for this panel
i would suggest that the AB21 would be most suitable for this panel
Many thanks
Nathan Swann
Q. Hi, I'm interested in purchasing a Texecom Premier 24 Kit, but was wondering could the 100m cable + cable clips be omitted and the price be reduced accordingly ? We already have the wiring in place. Thanks, John.
Good Morning John.
Yes you can- if you send your requirements in via email at support@support.alertelectrical.com.
We will then send a quote to you.
Kind Regards
Emma Stevenson
Q. I have an Ademco/Honeywell Accord XPC alarm system but at some point the speaker in the interal sounder box has been removed. What is the best option to repair as it is a very old system and I have not been able to find spares anywhere
Good Morning Sam,
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Q. Hi, are you able to print my company logo on any of the bell boxes you supply?
Good Morning Dave,
Yes we are able to do that,
if you send your Company Logo over to us Via PDF to Support@support.alertelectrical.com and your reqirements we should be able to get this sorted for you.
Q. I have an accenta burglar alarm system with an accenta eight control panel, the keyboard needs replacing, it is led 8 zone model do you have a compatible one for sale?
Good Morning John
The 8EP417A Keypad is the unit i would suggest is the most suitable for your unit
Many Thanks
Nathan Swann
Q. I have a scopetronic alarm and want to change the code number ... how do I do that?
Hello
Please contact CSL on this number 01594 545454 and they will be able to help you with this
Q. What is your usual postage time and do I need to be at home when the item arrives.
Good Morning Richard
Delivery is next day if the item is in stock and ordered before 2pm
it is advised that you are home on the day of delivery but if not a calling card will be left by Yodel and delivery can be rearranged
Many Thanks
Nathan Swann
Q. Can you deliver the Pyronx KX10 DP pet detectors and the Deltabell-E and plus whit Red basecolor. Regards.
Good Morning Cees
Unfortunately it is not something we do, we only do it with a blue base.
Q. Hi - I have placed an order via my account, but there are no details as to progress available. could you advise please? Many thanks
Good Morning Jonathan
if you could contact support@support.alertelectrical.com with your order number then we can advise further for you
Many thanks
Nathan Swann
Q. Hi does the veritas r8 plus come with a keypad as in the picture? If so is it the led keypad? Do you know if you can use both led and LCD in one system?? Thanks David
Good Morning David
i can confirm that this panel does come with an LED keypad
Many Thanks
Nathan Swann
Q. Could you offer me a code for free delivery please
Good afternoon Darren,
Unfortunately we don't offer any codes for Free delivery as all our delivery's are charged at £3.98
Please see the below link for all our delivery details
http://www.alertelectrical.com/3/delivery
Many Thanks
Nathan Swann
Q. There is a local branch in Leicester?
Good Morning Yash
the Leicester branch address is below
Leicester Branch
Unit 29 Gorse Hill Commercial Centre
Boston Road
Beaumont Leys
Leicester
LE4 1AW
Many Thanks
Nathan Swann
Q. Veritas R8 alarm, we had a power failure the alarm went off, I entered my code then pressed FULL waited 1 minute would not switch off ( trial and error it eventually switched off ) when the power came back on we switched power off to see if we could switch the alarm but again it would not switch off. I followed the manual but no sucess please help thank you Deborah
Good Morning Deborah,
unfortunately it is something that we will not be able to advise you on,
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Many thanks
Emma Stevenson
Q. I have purchased KIT 1 ALERT from you and used a 4 wire system (not connecting tamper ) on zones. On power up there is a tamper indication and zone 5 (unused) flashes. Can you explain this condition.
Good Morning Alfred,
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Many thanks
Emma Stevenson
Q. I have a Scantronic 9800 microprocessor alarm system. Does this conform with NACOSS or SSAIB alarm system. Do you maintain such systems and can provide a 24 hour call out service please?
Good Afternoon David
Unfortunately we are only an electrical wholesaler and not an alarm installer
Please contact your local Alarm installer for further information
Many Thanks
Nathan Swann
Q. Hi i am installing an ag6 external sounder and strobe . when i connect the battery link the siren starts immediately and does not turn off when the tamper bolt is fitted, any help would be great
Good Morning Kevin
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Many Thanks
Nathan Swann
Q. Please could you tell me what is missing of my delivery.
Good Morning Andrew
if you could email your order number to support@support.alertelectrical.com then we can advise further for you
Many thanks
Nathan Swann
Q. EWe have installed veritas 8 b a - how many access codes are available to us. We have a prime one but are seeking further codes - is this possible?
Good Morning Roger
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Q. Wher is my order Order: W20120303N37
Good Morning Nilesh
i can confirm your order is out for delivery today with Yodel
your tracking number is JD0002287693200673
Many Thanks
Nathan Swann
Q. Hello, I was just wondering why the wireless alarm and detectors I ordered have not arrived yet! I ordered it last week and it was supposed to be a next day delivery! I have checked my statement and you have already taken the money out of my account, yet I don't have the goods! What's going on?! If it's not here by Saturday 10 Th then I want to cancel my order and want a FULL REFUND and will take my business elsewhere!!! Regards Nilesh
Good Morning Nilesh
if you could email your order number to support@support.alertelectrical.com then i can look into this for you
Many Thanks
Nathan Swann
Q. Hi there could you confirm if ADE 8EP416 or ADE 8EP417A are compatable with our Concept 6? Cheers
Good Morning Chris
unfortunately this is not something we would be able to confirm for you
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Q. I am ordering a Honeywell Accenta 8SP400A-uk alarm control panel. What battery should I order with it that will fit into the box. Model of battery would be helpfull.
Good Afternoon Calum
the AB21 battery would be most suitable for this panel
Many thanks
Nathan Swann
Q. Hi there, does the deltabell decoy and come with a cover included?http://www.alertelectrical.com/prod/1898/pyronix-deltabell-decoy-bellbox http://www.alertelectrical.com/prod/1817/pyronix-deltabell-plus-bellbox Thanks
Good Morning
This unit does come with a white cover
Many Thanks
Nathan Swann
Q. I require a transformer for my Ademco Accord home security panel. I understand that the part, TU7-1230-9902-11157-1VMH, is obsolete, but may be replaced with a Texecom equivelent. are you able to supply the Texecom equivelent?
Good Morning John
Unfortunately this is not something we would be able to advise on as we have never supplied Ademco products
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Many Thanks
Nathan Swann
Q. Hello. Is it posibel to by without tax. Kim
Good Morning Kim
if you supply your vat number and order number on a email to support@support.alertelectrical.com we can deduct the vat from your order
Many Thanks
Nathan Swann
Q. My PIR on my landing is glowing red does this mean I need a new PIR or a new battery so that I can order. How do I know what type of PIR if needed to order? Can I just take it off to look at the number or detail? Please advise
Good Morning Stuart
Please advise on which unit you have so we can advise
if you could contact us at supoort@support.alertelectrical.com we can advise on this for you
Many Thanks
Nathan Swann
Q. I am about to order a system. including a Texecom Odyssey 1E Bellbox. Your information says I also require a 2.4ah back-up battery. I can only find a 2.1ah battery. Is this alright or do you also supply one that is 2.4ah?
Good Morning
That 2.1 will be suitable, there is no real difference to be honest.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hello, I wish to purchase 2 x Mercury 100Ib Pet Immune PIR, which you list on your web site. Can you tell me if they are available in stock please? And if not can you tell me when they will become available. Thank you
Good Morning David
Unfortunately these units are currently out of stock
once ordered delivery on these would be 3-5 working days
if you have any further questions please contact support@support.alertelectrical.com
Many Thanks
Nathan Swann
Q. How can I set delay entry delay time so that the alarm does not go on before I enter my code on the key pad?
Good Morning Robert
if you could advise on which alarm this is and email this to support@support.alertelectrical.com then we can advise further for you
Many Thanks
Nathan Swann
Q. I have a Securacheck 2 zone autoset alarm some 20 years old. (6 cable). I want to replace the panel with say Texecom Veritas 8. Bellbox with Texecom Odyssey plus dummy box and cable. To re-use existing PIRs and door contacts. Please can you advise.
Good Morning Derek
Unfortunately due to how old the existing system is i cannot confirm on whether this would be OK to do
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. I have a Paragon Plus intruder alarm system . The remote keypad is a Paragon RKP. I uderstand these are no longer available. Can you offer a direct replacement. The manufacturer is Pyronix.
Thank you for submitting a ticket to Alert Electrical Support, if you would like to contact Pyronix technical on the following telephone number 01709 700100 they will be able to advise you.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Alarm outside piping when off ?
Good Morning
We are wholesalers, we do not have the technical knowledge to help with this. It would help if you could provide further information such as what model your alarm is so we can direct you to someone who can help.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi I have recently changed my accenta g3 main box and keypads. Now every 20 mins the keypad bleeps twice all the time in day mode when the alarm is set it doesn`t do it. Hope you can help Thanks Barry
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi, I hope this isnt being too cheeky but i have searched for help with my alarm on the net and you are the only real site offering any advice. I have a Pargon super 2 alarm which was in my house when i moved in, we have now lost the code and recently set it off, the light on the outside is flashing it is not sounding outside but bleeps when we enter a room, from looking at the manual it looks like we have it on walkthrough mode. is there anyway of reseting the code? Hope you can help. Many thanks in advance
Good Morning Rob
if you would like to contact Pyronix technical on the following telephone number 01709 700100 they will be able to advise you
Many Thanks
Nathan Swann
Q. I HAVE AN INTELLISENSE PANEL WITH ULTRACELL 2.4AH APPROX 2.5 YEARS OLD. BATTERY IS NOT FLAT AND IS BEING CHARGED. ALARM SOUNDS DURING POWER CUT. I HAVE A DIALLER WITH IT SO I KNOW WHEN IT SOUNDS. WHY IS THIS ? COULD IT BE THE BATTERY NOT HOLDING CHARGE ? THANKS
Good Morning
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Is it possible to use the Pyronix Sterling 10 Control Panel to operate the sensors etc. from the Paragon TM Plus system that is no longer made?
Thank you for contacting Alert Electrical Support, if you would like to contact Pyronix technical on the following telephone number 01709 700100 they will be able to advise you.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Do you still sell the Paragon TM Plus burglar alarms and hold spares for the product?
Good Afternoon Mary
Unfortunately this item has been obsolete for many years and we would carry no spares for this
Many Thanks
Nathan Swann
Q. I purchased a texecom Veritas Excel alarm system. When the system is fully set the external bell operates as soon as an alarm is detected. When the system is part nset only the internal sounder operates. Is this correct or should the ecternal bell operate after a time delay?
Thank you for contacting Alert Electrical Support. If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Thank you for your enquiry.
Kind Regards
Stacey Harrow
Customer service advisor
Q. I want to order on line from Bangladesh. How will the carriage to Dhaka by air calculated, If by weight , please let me know the rate/kg . The items I am interested are mostly: 1. Alarm control panels 2. Detectors 3. All alarm accessories Even if I know the rate , how will the carriage be calculated and payment made .
Good Morning
Unfortunately we do not supply to Bangladesh at this time so are not able to help you.
Kind regards
Stacey Harrow
Customer service advisor
Q. I have purchased a Veritas R8 with remote keypad. can i operate my system using thisremote keypad alone, or have i made a mistake and should I have also purchased the veritas excel kepad instead? can i operate my veritas R8 with just the one basic kepad without the display?
Good Morning Peter
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Many Thanks
Nathan Swann
Q. I'm Ordering 3 complete Burglar Alarm systems. Can you either deliver after 5pm or let me know a date of delivery? 07956318070
Good Morning Paul
If you would like to contact Support@support.alertelectrical.com we can advise further on this for you
Many Thanks
Nathan Swann
Q. How do i disarm my texecom security alarm
Good Morning Alan
If you would like to contact Support@support.alertelectrical.com with we can advise further on this for you
Many Thanks
Nathan Swann
Q. Need to reset my gardtec 593, i only have the user code but not the master code
Good Morning Jagdish
Unfortunately as we do not sell any Gardtec items its not something we would be able to advise on
Q. How can i change the passcode on my pyronix matrix alarm I cannot see it any where on the user manual,.
Good Morning Haroon
If you would like to contact Support@support.alertelectrical.com we can advise further on this for you
Many Thanks
Nathan Swann
Q. We have a Scantronic 9800 burglar alarm and over the years the keypads have worn. We are aware that this has been discontinured and wonder if its possible to fit a keypad from a different scantronic model
Thank you for submitting an enquiry to Alert Electrical Support, if you would like to contact Scantronic technical on the following telephone number 01594 545454 they will be able to advise you.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Does the http://www.alertelectrical.com/prod/344/pyronix-belle-sterling-10-control-panel come complete with a remote keypad and if not which one would be suitable.
Good Morning
I can confirm that this panel does come with a remote keypad.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Do you do a stick on sign for bell box
Good Morning Fred
Its not something that we do but if you contact Support@support.alertelectrical.com we can advise on who you would need to speak with to obtain this
Many Thanks
Nathan Swann
Q. Good morning, we are looking to purchase a kit 2 accenta G4 alarm With the lcd remote pane[on some photos i think it shows a led panel as we would like a lcd panel do you get a lcd with the kit 2],is this system one of the latest sysytems?and is there any difference between the lcd panel and the led one ,thankyou sam
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind Regards
Stacey Harrow
Custoemr service advisor
Q. Hi I have a Texecom veritas R8. Will it work with a accentra keypad. Regards John.
Good Morning
Texacom products are not compatable with non-Texacom products so would not work.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi I purchased an alarm kit from you just about five years ago. Is it time to change the battery in the control panel. Can you supply a replacement, and how do I change it. There do not appear to be any notes on this in the texecom installation manual, the control box has I know a tamper switch, how can I remove the cover to chech the model number. Also there is a constant humming from the box, I suspect a relay, is that something I could change myself if you supplied the parts. Regards
Good Afternoon
We are not alarm installers so do not necessarily have the technical knowledge to provide you with such advice. It may be useful however to establish what make of alarm you have to try and help you.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. How do I print off a proper VAT Invoice Which must of course carry your address and VAT reg No
Good Morning Alan
if you would like to contact support@support.alertelectrical.com with your order number we can email you a copy vat invoice
Many Thanks
Nathan Swann
Q. Please can you tell me if the order has been despatched and what date I will recieve W20120105N81 Kind regards Victor
Good Morning Victor
If you would like to contact support@support.alertelectrical.com we can advise on the status of your order
Many Thanks
Nathan Swann
Q. Hello Will the texacom odyssey 3e 109db external sounder work with the texacom excel burglar alarm and can the sounder have the alert graphics added. Regards Phil
Thank you for contacting Alert Electrical Support. If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer Service advisor
Q. I have changed by keypad to a new keypad because the buttons were knackerd, and when i have changed it over and put the power back on, the keypad hasnt lit up?
Good Afternoon
Unfortunately as we are wholsalers we do not have the technical knowledge to know why this would be, you may need to contact an electrician or an alarm installer in your area to clarify what the issue is or perhaps the manfacturer of the alarm system.
Thank you for your enquiry.
Q. New customer require batte y 1.3amp
Good Morning
Please see link below to a battery I think you may be enquiring abourt.
http://www.alertelectrical.com/prod/307/1ah-12v-back-up-battery-for-burglar-alarm-control-panels
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. I have a Veritas 8 BA and the panel has developed a hum/buzzing noise what could be causing this?
Good Morning Steve
Unfortunately its not something i would be able to advise on
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. I have an intellisense 700L burgulary alarm fitted to a house I gave just bought. I don't know the code to turn it off once the power is turned on. How do I get a new code ??? Thanks Daniel.
Good Morning Daniel
unfortunately we don't have any information on this unit
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Q. Line one of second paragraph, 'know one at home..............' NO ONE at home is the correct spelling :-)
Good Morning
Please Advise on which order number this relates to and email into support@support.alertelectrical.com
Many Thanks
Nathan Swann
Q. Hi, Tha alarm goes off when we have a power cut. Think I need to replace a bettery on a sl compact alarm. What battery type do I need and where can I get one. Kind regards
Good Morning Gail
Could you advise on which panel this is so i can suggest the correct battery for this
SL compact is not one i can see in any of our listings
if you could confirm and email into support@support.alertelectrical.com we can advise further
Many Thanks
Nathan Swann
Q. I Have a Veritas R8 keypad with pir sensors. I need to disconnect the sensor in the garage. If I unset control panel can I remove the sensor in garage. Thanks
Good Morning David
Unfortunately this is not something we can advise on for you
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Many Thanks
Nathan Swann
Q. I have a honey well galaxy 2 seies what is the master reset code
Good Morning
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hello I have Microtec 4000 alarm system made by Itec security products. The bell box is u/s, can you recommend a replacement? Also have you any idea where I can get information to change the code? The code I have works but I want to change it. Thank you
Good Morning
Unfortunately we do not deal with this make of alarm and do not supply anythiing suitable for it. We are aware that they are still around, it may be worth speaking to the manufacturers of the item.
Thank you for your enquiry.
Kind regard
Stacey Harrow
Customer service advisor
Q. I have a securit 800l control panel alarm system. Unfortunately I do not have the 4 digit code to activate the alarm system. Can you help on hoe to reset. I have the C&K Securitech user manual, but it doesn't tell you how to reset tha system without the original code. Any help would be gratefully recieved.
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Forget password. How to reset alarm
Good Morning
Can you provide further information please so we can provide you with correct information.
Kind regards
Stacey Harrow
Customer service advisor
Q. I am looking for a replacement battery for my Pyronix Sterling 10 control panel. However the one I think I need on your website seems to be of a size that won't fit in to the control panel that I key the code in to. Am I looking at the wrong battery, the 7.0ah 12v Back Up Battery For Alarm Control Panels - AB7, or am I looking in the wrong place totally in the panel? Thanks in advance. Neil
Q. Interested in veritas 8 plus, will this replacement panal call my mobile or is more equipment required
Good Morning John
If you added the TSD or GJD700 units these will work with this panel to call your mobile
Q. Hi There, I've purchased a 8EP396A-UK complete Kit. I'm having problem folowing the wiring on External Siren (bell - AG6). I have folowed the wiring diagram but only able to get Strobe light to function. No Siren ? The Siren Bell is AG6 model. Is there an update upon wiring the AG6 Bell ? Thank you chris
Good Morning Chris
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Q. Hello, i m an installer from belgium i see its possible to order with you. but do you know if the texecom products are incert approved?? kind regards
Good Morning
We do supply to customers through most of Europe soyou can order from us, in regard to the Texacom product, please call Texacom on the following number 01706 220460 they will be able to advise you further.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. WHAT DO I NEED TO DO TO REST MY BURGLAR ALARM I DO NO HAVE THE ORGINAL CODE
Good Morning Parveen
if you could send an email to support@support.alertelectrical.com and advise on which panel you have we can advise further
Many Thanks
Nathan Swann
Q. Hi I have a C&K Securitech 700l system. Could you please tell me what battery (capacity and dimensions) I need for the backup. thanks
Q. I have a Accenta 8 control panel with 2 keypads ,, the alarm sounder out side is produceing a faint bleeping siren , i have checked fuses etc inside control panel all ok ,, i checked power supply to batt at terminals on the board shows 14v ok ,, but i don't seam to be getting any too the terminals next to them ,,, i have checked keypads visully and there is no power lights ,, any idea what next thankyou mick
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi, Apologies I should have told you the system I have, It's a Honeywell ADE gen4 system with an LCD keypad. The entry/exit tone worked until I inhibited the offending PIR now only the exit tone works. Looking at the manual on page 40 it mentions silent timed, is this where i need to re enable the tone on entry. Regards, Frank Mooney.
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey harrow
Customer service advisor
Q. Dear sir's, I purchased my system from you last year, a fault has developed on one of the PIR's. To enable me to use the system while I wait for a replacement I programmed the offending PIR out, since I have done this I seem to have lost the entry tone, how can I re enable this. Regards, Frank Mooney.
Good Afternoon
We do not have the technical knowledge for this unfortunately, can you advise what brand of system you have and we can put you in toch with the manufacturer.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi I need to replace a 4 zone panel and remote keypad with a new system. The original is an SL compact. I have previously purchased from you the scantronic panels which I find good and reliable but the customer is interested in having a communicator to notify him of an alarm. Can you recommend the best system for doing this? Many Thanks Nick Williams
Good Afternoon
Please find links below to the best system for the requirements plus a link to a communicator compatible with the system.
http://www.alertelectrical.com/prod/944/scantronic-8-zone-control-panel-with-9941-rkp-english
http://www.alertelectrical.com/prod/1405/gjd-gsm-speech-and-text-autodialler
Kind regards
Stacey Harrow
Customer service advisor
Q. Evening Support Team. I have purchased and installed a Speech Dialler ( Code TSD?) All set up and commissioned ok, dails out ok with no problems except it interferes with the phone system on incomming calls when in the standby mode.. Both parties, caller and receiver, only hear a high pitch tone, and the phone will only ring one or two times. I have broadband so the phone is connected via a filter. I have tried connecting both phone and dialer to one filter vie a double connecter, also tried using the double connector in the phone socket and using two filters to separate the kit. This makes no difference. Sorry this has been a bit long winded but, wanted to give you as much info as possible. Hope you are able to assist. Kind Regards. Alan.
Good Morning
I am sorry to hear this, unfortunately we do not heve the technical knowledge on this to know what the issue could be, I suggest you speak to Texacom on 01706 220460 to discuss the situation to find out what the issue could be.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Have a an Accenta 8 system fitted, which I understand is now obsolete) still works fine but keypad is bit dicky with keys sticking. Hard work with the onset of arthur itis in the fingers!!" Be pleased if somebody can tell me if the new available key pads are compatible with this system. Many thanks
Good Morning Morgan
Unfortunately this is not something we would know
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Many Thanks
Nathan Swann
Q. I had an alarm system with a sounder and strobe from Elmdene. I bought an Accenta G4 system and hooked it up to the old sounder. Everything works at the right times but the sounder is very quiet, you can hardy hear it in the house. Have I possibly wired it incorrectly or does it just need replacing?
Good Morning Allan
This Does sound like the bell box would need replacing
i would suggest the 8EP420 or the AG6 as most suitable bell box's for you system
Many Thanks
Nathan Swann
Q. Engineers reset code
Good Morning
Please clarify your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. How do I power down the Veritas R8 alarm system so that I can replace a faulty internal PIR? Strangely, neither the installation nor the user manual contains any advice on doing this. I need to avoid setting off the alarm as well!
Thank you for contacting Alert Electrical Support. If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer Service advisor
Q. My brother past away in may & i have no idea what is his yale alarm number is. how can i reset it
Good Morning
I am sorry to hear this, however, we are electrical wholesalers, not alarm installers so unfortunately we would not know. I suggest you contact the manufacturer.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Have a scantronic 9651 but when attempting to exit 'installers mode' recieve an error on display saying 'battery missing' !!!! have checked battery output and voltage no problems with that... any ideas?
Thank you for your enquiry, unfortunately we are unable to provide technical information. If you would like to contact Scantronic technical on the following telephone number 01594 545454 they will be able to advise you.
Thank you for your enquiry.
Kind Regards
Stacey Harrow
Customer service advisor
Q. What is the REPLACEMENT for wireless PIRs for a 4700 system, already fitted? I require TWO units
Thank you for submitting a ticket to Alert Electrical Support, if you would like to contact Scantronic technical on the following telephone number 01594 545454 they will be able to advise you.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi I have is an Accenta G4 Mini control panel and want to fit 2 Exodus OH/4W smoke detectors, the connectors in the smoke detector are: Latch Input, 12V, 0V, No Connection (Use for loop through if required), A & B: Alarm relay normally closed open on alarm. How do I connect the smoke detectors to my panel? Many thanks for your help.
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind Regards
Stacey Harrow
Customer service Advisor
Q. II HAVE AN OMNICROM 9000 WHICH IS NOW OUT OF COMMISION IT IS HARD WIRED AND HAS A REMOTE PAD . CAN YOU SUGGEST A SUITABLE REPLACEMENT FOR THE OMNICROM 9000 CONTROL PANEL
Good Morning Derek
With regards to a suitable replacement the Scantronic 9561EN-41 would be the panel i suggest would be most suitable for your needs
Many Thanks
Nathan Swann
Q. i have just purchased a house it has a securit 802 control panel the previous owner died and we have no codes to set alarm- is there a default code for the alarm so that i can put my own code in
Good Morning Glynis
Unfortunately we do not have the information on this panel to be able to advise further
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Many Thanks
Nathan Swann
Q. I have a Paragon alarm (at least 12 years old). Recently the front door bleeper when I re-enter the house isn't sounding (so I sometimes inadvertently set off the full alarm by forgetting to input my code). There are two brown plastic bits that marry up at the bottom of the door which appear to be the bits that recognise the door opening and would usually trigger the alarm. Any idea what the issue is and how it can be rectified? Thanks.
Good Morning Toby
Unfortunately we are unable to advise on this as this panel has been obsolete for a few years now
if you would like to contact Pyronix technical on the following telephone number 01709 700100 they will be able to advise you
Many thanks
Nathan Swann
Q. Ive recieved my 2 ade simple key fobs, but cannot find in manual how to activate them. i think you just hold them to the panel , if that is correct the panel keeps flashing on the error light.
Good Afternoon
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry
With kind regards
Kerry Wesseldine
Customer Services.
Q. I have a Logic 4 control panel on my alarm system. During the night with the alarm set to protect zone 1 (downstairs only) the delayed entry warning buzzer sounded and after the timeout the full alarm sounded. The delayed entry is wired up to a PIR detector. Please any suggestions will be appreciated
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind Regards
Kerry Wesseldine
Customer Services.
Q. I have a Honeywell XL-21 homa alarm sytem for the home. i have 3 keypads and one is or seems defective. The zone lights all stay on and the pad does not respond. Through the other 2 keypads I am able to set and take off the alarm. What can I do do reset this keypad or is it faulty
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Have installed honeywell optima with lcd keypad but cut through 1 cable , keypad says tamper lockout , replaced cable still same , on removal of keypad from system the system works fine , but on reconnecting keypad back up , says sameand cannot be set , is there any way to clear fault
Thank you for contacting Alert Electrical support. If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required.
Thank you for your enquiry.
Kind Regards
Stacey Harrow
Customer service advisor
Q. Hi can you supply a user manual for a scantronic 9427 style or tell me where i can get one please
Thank you for submitting a ticket to Alert Electrical Support, if you would like to contact Scantronic technical on the following telephone number 01594 545454 they will be able to advise you.
Thank you for your enquiry.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi there,my alarm activated when the the glass fuse went in the main wiring box,i have replaced this and when i went to the control panel it was all lit up and would not reset when i put in my code.the alarm is an intellisense securit 800,any help would be much appreciated.regards derek
Good Morning
We as wholesalers do not have the technical knowledge to be able to deal with faults. As far as I am aware though, this particular alarm system is obselete, I suggest you call Honeywell on 0844 8000 235 and they should be able to advice you.
Kind Regards
Stacey Harrow
Customer service advisor
Q. Hi i haved just moved into my new home its fitted with a kes alarm system the control panel is a optima xm6 i do not have the code to reset it or even to change it any help would be nice
Good Morning Matthew
Unfortunately this is not something i could advise on this
If you contact the manufacture Honeywell on the following number 01698 738509, they will be able to give you the technical advice required
Q. I have a Texecom Premier 24 alarm showing a message RKP 1 Tamper as i removed cover while painting. How do I reset please ?
Good Morning Gerry
Im not 100% on how you would remove this fault
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Many Thanks
Nathan Swann
Q. Hi, I've just installed a Scantronic 9448EUR95 Burglar Alarm Kit. The alarm is working fine, but I can't use the panic alarm. When I press key 1 and 3 simultaneity nothing happend. I don't have any sensor for zone 6, the zone 6 is set as PA. Can you let me know, please what should I do? Thank you, Ion
Good Morning Ion
what i have done is sent you an installation manual for this panel as it should provide better information on this for you
Q. We plug our wireless audio transmitter into the kitchen sockets and it turns on but nowhere else in the house. Why?
Good Morning
Could you advise on which item it is you have so i can advise further on this for you
Many Thanks
Nathan Swann
Q. I HAVE JUST MOVED INTO 53 ROSSES MEADOW BALLYMENA AND WANT TO RESET ALAEM SYSTEM BUT AM NOT ABLE TO GET LAST ACCESS NUMBER FOR ALARM WHO DO I CONTACT IN THIS AREA BT422SD
Good Morning
could you advise on the type of alarm you have or manufacture of the panel so i can advise for you
Q. I have a accenta8 alarm system fitted but I believe the remote key pad is faulty .I have checked for power to the key pad and that ok but the power light is off Keypad code 2BF072 is there a replacement for this keypad If not could you advise me of an alternative CPU replacement with remote keypad which will accommodate all the ancillary fittings. Regards Paul Fisher
Good Morning Paul
as the Accenta 8 has been obsolete for a few years now i would suggest a replacement panel would be the best route to go down
i would suggest the 8SP401A would be the most suitable as this was the replacement for the Accenta 8
Q. Thank you Nathan, but could you tell me if i could reset the system using my security code for the remote key pad or would i have to get an engineer out to reset the system? Kind Regards, Neil
Good Afternoon Neil
The code for the remote keypad is the main code for the system so yes you can use this to reset the system
Q. Can i replace a defective texecom reflex pir fitted to a veritas R8 alarm system without the need for an engineer to reset the system.
Good Afternoon Neil
Unfortunately you would have to Reset the alarm in order to add this item on to the system
If you have any further questions please let me know
Many Thanks
Nathan Swann
Q. Do you stock a remote keypad for a Securit st802 intruder alarm
Good Morning
After Checking with Honeywell the manufacture of this item i have been advised that spares for the SEC802 & 800L are no longer available as these units have been discontinued
Many Thanks
Nathan Swann
Alert Electrical Wholesalers
Q. We have a VeritasR8 alarm fitted in one of our secure rooms.Could you tell me if the alarm switches itself off after a certain time once it has been activated either by accident or design. Thank You & Regards, David Waller.
Good Morning David
looking through the information i have on this i cannot see why the alarm would turn off after a certain time
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Q. How to design a home burglar alarm system
Survey your home and determine how many windows and doors you want to be protected by your home security system.
Determine possible locations for the control panel and keypads. You might find it convenient to place a keypad close to the front door. You might also want a keypad close to the bedrooms. The control panel is the 'brains' of the system, and the keypads allow you to program the control panel and turn it, or its components, on and off.
Determine how far away windows and doors are from the control panel so that you know how far burglar alarm cables will be routed if you choose a wired alarm system or how far a wireless system needs to communicate with sensors. Bare in mind that it can be difficult to install a hard-wired security system unless your house is still under construction or you plan to re-decorate.
Decide whether you want a monitored security system that will be monitored 24 hours a day. The central monitoring station 'watches' your home for a monthly fee. Burglar alarm systems monitored by a central station should be installed by a professional burglar alarm installer. A less expensive alternative is a basic sensor system with a telephone autodialer that connects the system to your phone lines and dials preselected numbers if the house's home alarm is breached.
Consider your lifestyle. Does anyone in the family often get up in the middle of the night for a snack? Do you have a large pet that roams the house at night? Such circumstances will influence the type of motion sensor you select and how it is installed. It may also call for you or members of your family to take trips to the keypad to prevent false alarms.
Choosing a System
Choose a system with a control panel that can monitor all the zones you have in your home. Each window or door integrated into the system is considered a zone. A basic system is capable of controlling eight zones. However, many panels, like the Texecom Premier series, permit the addition of expansion modules that allow the system to watch up to 32 zones.
Determine if the routing of the wires for a hard-wired security system might be too long. With a wired system, you will have to drill holes in walls where wires will have to be routed. If the wire run appears too long to you, choose a wireless system. Make certain that a wireless system can perform up to the distance of the farthest zone although this can be increased by use of a range extender.
Be certain that the system you choose can accept fire-protection sensors, carbon monoxide sensors and combustible-gas detectors, anti-freeze-up low-temperature switches (especially in cold climates) and water detectors. Make sure that panic buttons are or can be included.
Choose a system that is user-friendly. Make certain that inputting codes into the keypad is not a complicated process and is one that everyone in the family can learn quickly. You don't want to have to refer to the owner's manual as you input or try to interpret codes.
Work the keypad of the system you select to assure yourself that it is easy to use. Encourage all family members to work the keypad so that you will select one that everyone can use comfortably.
Q. my verates 8c control panael has just given up the ghost after 9 years of service. Does this mean I have to buy another or do I need a new battery which has never been changed?
Q. where can i get hold of a user manual for a veritas 8c
Q. i can not reset my pcx-12 alarm as i have no manual canyou send me a manual please
You can access a user manual by following this link http://www.alertelectrical.com/4/faq/cat/22/manuals-and-user-guides#answer and navigatig down the page to the Pyronix section. If it is a engineers manual that you require you should contact Pyronix directly. Thank you for your enquiry.
Q. Sorry to ask could you confirm if my order might be delivered tomorrow as I did not meet the 2pm deadline? order ref W20101209N42 Best Regards Andrew Masters
Good Morning
Unfortunetly this order did miss the deadline and delivery would now be monday
Q. Can you recommend a good burglar alarm to make a residential alarm system please?
Most of the burglar alarm components that we sell on alertelectrical.com will make a good residential alarm system. To make your selection easier we have tried to assemble some complete alarm systems from the most popular manufacturers like Texecom, Phttp://www.alertelectrical.com/prod/986/pyronix-sterling-10-lcd-intruder-alarm-system-kityronix and Honeywell ADE. Each and every home is different so you should customise each kit byadding your own extra components to suit your individual circumstances, like a telephone autodialler that will telephone pre-determined numbers in the even of the system going in to alarm.
Q. Alarm system is Veritas R8 Plus.the system has 3 PIR. Every now and then the internal sounder of the alarm sets itself off.The system does not accept my code to stop . It does however eventually stop by itself. I bought the house only three years ago and the house is about 9 years old.Should I be changing the battery to eliminate the problem Regards
Q. I have an Infinite Wireless Burglar Alarm System. I recently had all new external doors and windows fitted to my property and I removed serveral sensors in order for the work to be done. I deleted the devices but now cannot reinstall them I have tried initialization of the system but it still does not register the transmitters. The system reports that there are no devices. Can you please advise. Thanks CM
Q. I do not have any instructions for my alarm system. The control panel has the name C & K Securitech and the box on the outside of the house has the name Detec. Can you please help
C&K Securitech are now owned by Honeywell. You can download user guides for the C&K Securitech SEC800L and Securit 802 on our Honeywell Burglar Alarms userguides download page.
Q. I had a Texecom Veritas R8 alarm system fitted 12 years ago when we moved into new house, we have had no problems until recently when tamper light flashed up and now unable to set alarm. I have called an electrician out who has tested various things and now is requesting an engineering manual so he can get access to enginering code. Is there anywhere i can get a copy of the engineering manual? The electrician who fitted the alarm doesnt work at company any longer?
Q. I am looking for an alarm system that works outside - it senses movement before anyone reached your door. Up to 50m or more metres away. Possibly a 4 - 6 zone setting. What would you suggest and cost please? Also can I set it up myself? Thank you.
Takex Beam detectors are designed to be used outdoors and trigger an alarm system when the beams are broken. You need to connect it to a burglar alarm control panel in the same way you would normally add a detector to a burglar alarm system. You can find prices and specifications by clicking on the link. Thank you for your enquiry.
Q. hi there , wonder if you can help me please. my present alarm system is fitted with a pyronix magnum ' e ' pir's and at this present time one of these has gone faulty. i understand you stock the magnum 'e' meq blue pir that i understand is compatible. would it be possible to confirm this is so and if so do you carry the same in stock and what would be the costs etc. thank you in anticipation
Good Afternoon Michael Thank you for your email, if you click on the following link to the pir's we have these in stock delivery would be next day. Delivery on this would be £6.00+vat . Please don't hesitate to contact us if you require any further information.
Q. Hi, Nowhere can I find the dimensions of the "Activ8 360 PIR"? Could you please let me know the diameter of this sensor.
Thank you for your enquiry, i the dimensions for the Activ8 360 PIR are Depth = 110mm Height = 45mm If you click on to the following link you will see the specifications for the detectors.
Q. How do I protect a window? Is there something better than a magnetic contact ?
Advantages: Cost effective, reliable
Disadvantages: Labour intensive, only monitors openings, not the glass itself
Advantages: Very good for covering a small area including openings and glass, time saving.
Disadvantages: Need careful setting up.
Advantages: Very good for detecting the sound of glass breaking over a fairly large area. Easy to install.
Disadvantages: Only monitors for breaking glass, does not detect forced opening.
I hope that helps
Q. I have a 9800 panel which was fitted in approximately 1992. The panel needs to be replaced. Please can you advise which current model of panel best matches the 9800, to minimise rewiring the house?
Thank you for your enquiry, if you click on the following link to the Scantronic 9651 this would be a suitable replacement for your control panel. http://www.alertelectrical.com/Burglar-Intruder-Alarm-Systems/Alarm-Control-Panels/Scantronic-burglar-alarm-panels/Scantronic-9651EN-41-8-zone-control-panel-with-9941-rkp---English-9651EN-41.asp
Q. I am just wondering if you could help me, I am looking to purchase an alarm system from yourselves but would like to know what you would recommend. First of all I am wanting to install this myself so I would require something not to difficult for a DIY installation . I would need a system to cover 5 zones (3 x PIR and 2 Door Contacts), I would also like to have a chime facility on one of the zones, our living room is in the middle of our terraced house so it would be handy to have so we know when the front door is opened. I would also like it to have a remote keypad to keep things nice and tidy. I would also like to omit zones at night so that it can be set when we go to bed. I have looked at your Avanti LC Home Burglar Alarm System With LCD Remote Keypad but would still like to know what you recommend. I noticed there is an option with this panel that you can have a fob that does a night time and day time activation and feel this would make it really simple for my wife to set (I work nights and I think she would get stressed trying to remember two different codes for two different types of activation). If at all possible you could help me that would be most appreciated. Would you also let me know how long it takes for delivery as I am going to require one asap.
Your requirements are straightforward and within the scope of our standard systems. To create a chime facility you need only to set the required zone as ‘entry/exit’ and then set it to chime. The problem with the Avanti LC system is that the instructions are a little bit brief. They do however have an excellent technical helpline open 9am to 5pm Monday to Friday. The other option would be the Kit 4 Texecom VR8 kit which is a similar specification to the Avanti system but with slightly more comprehensive instructions but it doesn’t have LCD rkp. The ‘Red For Bed’ tag facility is unique to the Avanti system I think you would probably be best going with the Avanti system.
Q. Could you please advise on what type of PIR detector I should use with the Scantronic 9751 alarm system and whether I need any other components for a house alarm system
Thank you for your enquiry, any of the wired pirs will work with the panel, if you click on the following link to our range of complete alarm kits this will give you an idea of what is required.
http://www.alertelectrical.com/cat/2/complete-burglar-alarm-systems-and-kitsQ. Does the Texecom Veritas R8 burglar alarm control panel include transformer and battery ? If not which transformer and battery would i need ?
Many thanks for you're valued enquiry. The VR8 includes a transformer in the panel, but you would have to purchase the battery seperate. If you click on the following link to the battery required 2.4ah 12v Back Up Battery For Burglar Alarm Control Panels - AB21. Please do not hesitate to contact if you have any further questions, assuring you of our most careful attention at all times,
Q. I have a 9448+style unit fitted to my house. I have recently had an extension added to the side of the garage (not attached to the main house), can I buy components such as additional PIR sensors which will attach remotely (possibly by radio signal) to the main house system. Alternatively is there a seperate system which can be purchased which has its own key pad/remote control for set/disarm which can have an external alarm siren and an internal (inside the house) siren. Could this system be a wireless system?
You can use an Infinite 8 channel wireless receiver for Infinite wireless detectors. These are designed to be added to an existing burglar alarm to give wireless burglar alarm detector functionality.
Q. The original wireless systems were prone to being scanned by burglars for the input code. Is this still a problem or has this now been resolved. How safe are they now.
It is true that wireless alarms built up a reputation for being unreliable and prone to false alarms. However, at least for the last 10 years, as long as the alarm purchased is of reasonable quality you will not have a problem with a wireless alarm and you certainly will not have a problem that a potential burglar could compromise a well designed installation. The old wireless burglar alarms used to run on 468mhz which was shared by many other wireless devices but modern wireless systems have come on a long way since they were first launched. The Infinite uses 868Mhz FM to create a strong clear signal for up to 200m in free air, or approximately 90m through walls depending on conditions. The control panel has a signal strength indicator allowing easy determination of these factors. The FM transmitters within the system have high security data encryption making use of a rolling code facility which makes the chances of any other transmitters accidentally using the frequency highly unlikely, in the ratio of 1,000 000s : 1.
Thank you for your enquiry.
Q. Please can you tell me if its possible to buy a replacement c& k 700L alarm keypad, as ours is old anyway with some keys worn out and has recently blown up - during snow we had a power cut and it set alarm off and half the panel doesnt light up now and it won't operate the alarm! thanks
Thank you for your email, if you click on the following link http://www.alertelectrical.com/Burglar-Intruder-Alarm-Systems/Alarm-Control-Panels/Intellisense-Securit-control-panels/Intellisense-Securit-800L-Remote-Keypad-SEC800LRKP.asp this keypad is compatible with your panel.
Q. Hello, i would like to know if detectors exist for the outside of the house (to install in the garden for instance). what price is it ? thank you
Hello. Yes, Takex manufacture a range of beam detectors specifically for outside use. They should be connected to a spare zone in a burglar alarm control panel.
Q. Could you tell me please does the 9448eur90 panel come with a battery?
Hi
No the 9448eur90 does not come with a back up battery, you should order an AB21.
Thank you for your enquiry.
Q. Hi I have a Paragon Plus alarm system installed and would like to know if I can still purchase the alarm panel as the one I have has finally given up the ghost. If not is there a replacement I can purchase that is very similar.?
Thank you for your email, unfortunately the panel is now obsolete, you could replace the panel with any of the wired panels have a look at the Scantronic 9448eur-90 or the Texecom V8C. Both of these panels would be a suitable replacement. Please don't hesitate to contact us if you require any further information.
Q. I have an Optima Compact and I believe that the Back-up battery has failed. Most of the lights are on and none of the buttons are working. I recently had a new electricity meter fitted and it failed immediately they finished fitting it. Firstly, do you think I may be correct in assuming that the battery has expired and secondly, do you sell them, and if so at what price including postage.
Yes sounds like the battery if you click on the following link to the replacement battery http://www.alertelectrical.com/Burglar-Intruder-Alarm-Systems/Burglar-Alarm-Batteries/21ah-12v-Back-Up-Battery-For-Burglar-Alarm-Control-Panels-AB21.asp Delivery would be £6.00 + vat. Please don't hesitate to contact us if you require any further information
Q. i was wondering whether you could give me some advice before ordering ,will the infinite wirefree sounder work with a accenta g4 wired system ? if not do u do one ? would you still need to run a wire from the control panel to the loft for the bell box ?
If you already have an Accenta G4 then your only option will be to hard wire a bell box or start again with a wireless system that can take a wireless bellbox. Infinite do manufacture a retrofit receiver for hard wired systems like the ADE Accenta but this is for wireless detectors and not for wireless bellboxes.
Q. We have a scantronic 9455 alarm which requires a new battery can you tell me where I can get hold of one please?
Thank you for your email, if you click on the following link to the replacement battery required. http://www.alertelectrical.com/prod/563/24ah-12v-back-up-battery-for-burglar-alarm-control-panels
Q. I must have put in the wrong code and my alarm wouldn't stop, I managed to stop it but now it says Kitchen and if I go to kitchen it will go off what can I do to stop it?
First of all you will need your instructions for the alarm system. The control panel appears to be telling you that the zone marked 'kitchen'is being triggered. You should either clear the problem causing the alarm to trigger or consider omitting the zone temporarily to allow the system to be armed. The instructions for omitting the zone will be found in your alarm instructions. If you choose the latter option then you should immediately contact an alarm compancy to recitfy the problem with the zone.
Thank you for your enquiry.
Q. how do i change my alarm code on my veritas r8
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. do you know how to get a paragon super alarm back to factory settings., ive just bought a new house and i have no codes or instruction manuals. Thanks
Q. Does the 9651 Alarm panel with a 9943 proximity remote keypad come with any proximity tags?
The 9943 Keypad comes with one proximity tag
Extra tags are avaliable under part code PROXTAGPK5
Q. I have bought a 9ep502 avanti lc8 panel but have not got a engineer manual can i get one on line
Hi There
mdt Westech Avanti user manuals are available online but engineer manuals are only available with proof of purchase of the control panel to protect the security of the panels and systems that run with these control panels. Therefore if you could supply us with your order number we would be happy to supply you with the appropriate engineer manuals.
Thank you for your enquiry.
Q. where can I get a user manual/instructions for Scantronic 9427 keypad
Q. Does the Texecom Premier 24 require a PSU? 2. Is the Texecom 3 ah 12v battery (AB3) suitable for the Texecom Premier 24? many thanks, Nigel
No the Texecom Premier 2http://www.alertelectrical.com/prod/72/texecom-premier-24-8-24-zones-control-panel4 does not require a PSU as it has its own transformer inbuilt. It can take any battery form 1.2ah to 7ah so the AB3 3ah battery would be suitable
Q. Hi can you help me please Vetitas alarm system I need to replace the batteries in the external alarm/strobe light box. The batteries are corroded and I removed them for replacement. It looks like there are 7 small batteries sealed together and resemble a pack of polos (with positive and negative cables attached to each end) . On the side it is written GP 8.4v 280mAH GP280BVK X7 K6 Ni-cd. Can you please advise me where I can purchase replacement batteries or a part number which will enable me to buy locally. Many thanks for your help
Good Morning Dave Thank you for your email, if you click on the following link to the battery required.
www.alertelectrical.com/prod/2041/replacement-72v-nicad-batteryPlease don't hesitate to contact us if you require any further information. Kind Regards Sally Hughes
Q. Hi Could you please advise me on the correct PIR to use in a conservatory and do you sellthem if so how much. Thanks Brian
Hi Brian
The correct PIR for a conservatory should be one with a high immunity to thermal movement. Therefore in order of their ability to deal with heat I would advise the installation of:
1. A Dual technology detector with combined microwave / PIR detection
2. A quad PIR detector
The dual technology detector is immune as the microwave does not pick up heat at all. They are more expensive and the range of the microwave needs careful setting up as the microwave can go straight through walls and windows and be triggered by a movement on the outside of the property. Examples of these that we sell are: Texecom Prestige DT, Scantronic 280En, Pyronix KX15DT and the ADE Activ8 DT
The quad PIR detector is better than standard as there are dual beams to be triggered but not as good as the dual technology detectors, although they are generally a lot cheaper. Examples of these that we sell are: ADE Activ8 Quad PIR, Pyronix KX15DQ, Scantronic 220EN and the Texecom Prestige PRESQD
Thank you for your enquiry.
Q. I have a Veritas 8c compact. I have had to change the battery. But since then I cannot get it to work normally, the 24hrs light just flashes red. It will not harm up. I have tried switching the power off but this as had no affect. What needs to be done.
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Q. Can you tell me if it is at all possible to install a simple key operation or remote operation to a Pyronix Sterling 10 alarm system My mother has a Pyronix Sterling 10 installed and she wont use key pad supplied .
Thank you for your enquiry, a Pyronix reader may be suitable for you application. The other alternative is ESP Infnite Wireless Receiver which can be used in conjunction with an Infinte remote fob. This will give you the range to arm and disarm the control panel outside of the property.
Q. We have an Intellisense burglar alarm. Two sensors create a bleeping reaction when we walk past them even though the alarm has been de-activated for day time use. Any ideas why this is happening?
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required
Q. I have recently purchased your kit1 alarm system.I have a couple of problems,the first being that the online kit includes a battery,I didn't get one.Should it be included? The second problem is that the wiring instructions for the sounder do not match the terminal markings on the control box or the bell unit.Do you have the correct wiring details?
If you would like to contact Alert Electrical on the following number 0115 8715086 9am - 4pm Monday to Friday or at support@support.alertelectrical.com our sales team will be able to advise you further
Q. I have recently left a review for a texecom alarm panel. I was told I would receive a 5% discount off my next order. I have an order waiting to submit but I am not sure how I receive my discount, please. Thank you.
Good morning Richard
That's not a problem, if you can place your order via the web and then email us your order number informing us that you have placed the order and I have advised that you are to receive 5% discount.
I will then make the arrangement to take the 5% off at this end.
Kind regards
Stacey Harrow
Customer service advisor
Q. After a number of panel freezes and false alarms, I think it''s time to r eplace my alarm. I have a 1992 Europlex/Scopetronic HomeGuard. Could you please suggest a wired replacement system (simple requirements, just 3 zones) that lets me reuse existing wiring and detectors? Thanks
Hi Antonio
Any of our wired alarm panels will replace your old panel. My recommendation would be:
- Texecom Veritas 8C, they always come with comprehensive instructions
- Mdt Avanti 8 these panels come pre-programmed so it saves you having to do to much on installation.
Both panels have 8 zones but that is the minimum these days. They will both also need an AB21 back up battery.
Thank you for your enquiry.
Q. I have a veritas alarm, it keeps on going off ,so I think it needs a new battery but the company who installed it have finised business ,so I would like to replace it myself but I do not know how to take the battery cover off. can you help.
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. Hi Could you tell me please if I can use two bell boxes with any control panel or just with some. If so could you recommend which? Thank You
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. Could you possibly let me have the phone number for Scantronic . I have a customer support and also Admin number from 15 years ago, neither seem to be current. with thanks. Howard.
Good Morning
The number you require is 01594 545454.
Kind regards
Stacey Harrow
Customer service advisor
Q. Hi. I have just purchased KIT 1. The wiring diagram to join control panal to the AG6 is not right, The control box is marked T A D B S- S+ The bell box is marked. ST- R- SW- V+ V- could you please tell me which wires go where Yours Pete
Hi Peter
We had put the answer directly on to the product page for the kit 1 and Kit 2. To save you the time here is the connections:
Avanti should be wired to Intellisense Bellbox as follows:
Avanti Panel: T A D B S- S+ (S+ doesnt get used as Intellisense Bell doesnt have 'ind' circuit)
Intellisense Bell: T V- V+ SW Stb
Let us know if you continue to have any further problems, thank you for your enquiry.
Q. Can we purchase a panel for a Scantronic 4600 alarm system as ours has been affected by lightening?
Thank you for your email , unfortunately the Scantronic 4600 has been discontinued. You would need to purchase a new Scantronic alarm panel. Please don't hesitate to contact us if you require any further information.
Q. Looking to buy a Texecom Veritas 8 compact controller and accessories, I will need a backup battery - can you recommend the battery and do I need an enclosure/fitting kit for the battery as it looks like it will not fit inside the controller. I was going to use an external Texecom Odyssey 4 sounder inside the premises - can I attach two of these to the controller - one inside and one outside, or do you recommend a different solution - I want the alarm to be so loud as to make it very uncomfortable and disorientating for burglars inside the premises
Thank you for contacting Alert Electrical Support. If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Thank you for your enquiry.
Q. I recently bought an Mdt Avanti 8 burglar alarm panel from you, and I have fitted it succesfully. (I have fitted alarms in the past with no problems), however with yours I am having some difficuly setting it up. Firstly am I right in thinking that the engineer program has to be set up first, which I presume programs the zones, then the user or manager program is initialised ?
The new European Regulations means that unfortunately the status of alarm systems cannot be displayed to by-standers. All panels are now affected by this directive. With regards the programmes. Mdt Westech Avanti 8 is pre-programmed. Programme A (Away - Full Set) means that all 8 zones are protected. Programme B (Bed - Part Set) omits Zones 7 & 8. Programme * is left un-programmed. Within both programmes Zone 1 is Entry Exit, Zone 2 is Time Inhibited and all others are Immediate. The vast majority of installations are covered by these defaults and I would be very surprised if you had need to alter these. Day mode means that the alarm is not set. It will therefore only activate upon a Tamper or PA. Panels are either Set or in Day mode.
Q. I need a manual for a Veritas alarm unit.It is over 12 years old it may be an re model number.
Please click this link to Texecom User Guides. I think the download you are looking for is the second listing.
Thank you for your enquiry.
Q. Which replacement battery should I choose for the Intellisense Securit 802 control panel?
Q. How do connect the Avanti control panel to the Intellisense bellbox provided in your kits. I have had a look at the instructions but they dont completely match up with each other?
Over the last few days we've had a number of technical enquiries about connecting Avanti control panels to the Honeywell Intellisense AG6 Activeguard Bellboxes. The correct wiring should be the following:
Avanti should be wired to Intellisense Bellbox as follows: Avanti Panel: T A D B S- S+ (doesn't get used as Intellisense Bell doesn't have ind circuit) Intellisense Bell: T V- V+ SW Stb
Q. Hi, I purchased an alarm kit from you three years ago, consisting of a Pyronix Sterling 10 Control Panel, Pyronix Belle, PIR's and Door Contact Switches. Everything was okay until about 6 months ago, when the alarm actuated for no obvious reason and then soon afterwards showed a tamper fault. Despite many efforts to clear this, including disconnecting the tamper zone altogether and looping it out, the fault would not clear. Trying to set the Control Panel simply put it into immediate full alarm. Pyronix Help Line were completely unhelpful in assisting me and really couldn't be bothered. I eventually had to resort to leaving the Control Panel in Engineer Mode, (which bypasses the Tamper circuitry) to maintain a working alarm. Now I have the Fault Symbol (!) flashing on the keypad showing four possible faults, such as fuses, power etc. All of these are okay. Now after setting the alarm (in Engineer Mode), the Entry/Exit mode for the front door does not work and upon opening the door the system goes into full alarm (it is programmed correctly). Bottom line is, I think it's time to give up on this Control Panel and the Belle Box by the way, whose sirens no longer work. I want to keep my existing wiring, PIR's and Door Contacts. Could you recommend a replacement control panel, keypad and siren box for me. I don't want a complex difficult to wire system that only a professional could understand but I do want something that has good functionality, eight zones plus, expandable to include fire zones and that will last longer than three years. Obviously my experience with Pyronix's Help Line has not endeared me to them. Hope you can help. Many thanks David Tatum
Good Morning
The most suitable panel for your application would be the 8SP399A and a suitable bell box would be 8EP420
Q. Hi, I'm just looking at your burglar alarm kits and was wondering if you would alter from the standard or do I need to create my own. The kit I'm looking at is Kit 11 Texecom Excel Burglar Alarm System With LCD Remote Keypad but I would like to alter the 4 included PIR's for 6 Prestige PET Immune (code: PRESPW). I would also like to add a Spike Suppressor (Code: SUP) and Texecom bracket for prestige PIR (Code: AFU-0004) If you would be happy to amend the kit can you supply me with a price. Many thanks Steve
Good Morning Stephen
If you could contact support@support.alertelectrical.com a member of our sales team will be able to price this up for you
Q. i have a scantronic 9448 three zone unit approx 15yrs old. Recently the internal unit bleeps some 2/3hrs after being set,also one of the pir's fails to detect but sets alarm off if tampered with,the battery as never been changed could this be the problem. tried to check for battery but alam goes off if i try to open front .Please advise.
If you contact the manufacture Cooper Security on the following number 01594 545454, they will be able to give you the technical advice required.
Q. Approx 3 yrs ago I had a G3 alarm system installed in my home and now require to replace the battery. Unfortunately my installer died in a motor cycle accident. How do I install and what code do I use to keep the alarm from sounding as I do so.
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required.
Q. I am replacing my bell box for my Omnicron 7000 alarms system with Reason8. Can you confirm the wiring connections of the SCB of my original set up. 1. SCB RT = (-) RTN (T) Reason8 2. SCB O = (-) HOLD OFF (A) Reason8
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required
Q. Please can you advise when the current order will be despatched? I assume it did not leave on Thursday, so the next available day is Monday...Is this correct? Many Thanks Nige Chudley
Good Morning Nigel
i have just e-mailed you with regards to this order
Q. I have a Veritas 8c alarm. The outiside strob and sounder has stpooed working. I have checked the battery and is flat. Can I buy a spare battery or di I have to buy the complete board or is it a new sounder and strob if so can you recommend one that is compatible with Veritsa 8c
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. i have a scantronic 9247 alarm and there was a power cut and now my alarm wont set the out side box is flashing red please could you help me because i cant afford to get somebody out and cant afford to get a new 1 fitted thanks
If you contact the manufacture Cooper Security on the following number 01594 545454, they will be able to give you the technical advice required.
Q. we have been asked to install a burglar alarm for insurance purposes which needs to be approved by NACOSS, SSAIB or NSCIA. which is the cheapest sytem available on the market which fits this criteria? Is wireless more expensive?
You would need to contact a company that is NACOSS,SSAIB or NSCIA approved as it is the companies and not the systems that are approved. You will find these in your local directory.
Q. I have acquired a flat with an ADE Accenta 3 alarm but do not have the code. Where can I get information to reset the alarm system to a new code. I have the instruction leaflet
We have a page listing all of the ADE user guides for you to download. Please click the link.
Q. Hello, I wish to place an order that will be delivered to the Republic of Ireland. We are vat registered in Ireland and do not want to be charged UK vat. Can you please let me know how this order should be processed. Kind regards, Martin
If you contact Alert Electrical on the following number 0115 8715086 9am - 4pm Monday to Friday or at support@support.alertelectrical.com our sale team will be able to advise you further
Q. home alarm systems faq
A burglar alarm /intruder alarm is a proven deterrent against burglary and crime. There are two main types of burglar alarm, these are:
Bells only: - These systems rely on sounders to both deter the burglar and also warn neighbours of the intrusion. A system will normally have 1 external sounder as a minimum, this can be added to by having a internal siren as an extra deterrent inside the property, an additional decoy box on other exterior elevations to provide extra visual deterrent outside or an extra external sounder could also be used.
Monitored Systems: - These systems have all the features of the ‘bells only’ system with the addition of being monitored by a central station via a telephone line or radio link. When the alarm is triggered it sends a signal to the central station, which then notify the key holders and police of the alarm. These systems are a requirement of some contents policies, normally where this is the case it is also a requirement that an alarm installation company that is a member of an approved installations organisation installs them.
It is also possible to install a ‘telephone auto dialler’ onto a bells only system, which can notify a set of telephone numbers both static and mobile of the alarm activation. These have the advantage of immediate notification without incurring ongoing charges for central station monitoring.
The main components of a Burglar Alarm System are: -
Movement Detectors - to detect the burglar moving through the house
Door and Window Magnetic Contacts - to detect the opening of doors and windows
These are hard-wired or wireless radio-link to a: -
Control Panel - which processes the signals and sounds the bell or siren and/or alerts the Central monitoring station by telephone or radio link and/or alerts a number of people by telephone auto dialler.
Remote Keypad(s) - linked to the control panel so that the system can be set and unset by a code in different parts of the property
Bell or Siren - outside the property, out of reach of the intruder, a complete self contained unit with backup battery that will sound even if there is no power to it.
Whatever kind of system you have, it must be well installed and reliable.
It has to work correctly every time and not give false alarms.
Higher risk homes and business customers are investing in Closed Circuit Television (CCTV) systems. In this case you must decide whether you want surveillance of unauthorised activity or recognition of intruders.
Q. I have a Accenta alarm system, fitted approx. 1996. The bell box circuit board has corroded ( I think the part no. is 2BF 050/06/3-3) and no longer works. Can I obtain a replacement board or do I need to buy a new box? If a new box, which one is most suitable? Regards Arthur Jones
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required
Q. How many detectors do I need for my house or business?
PIR's or 'Passive Infra-red Detectors are one of the most secure methods of detecting intrusion within the house. They monitor the background infrared level and when this level changes by someone, or something entering the monitored area, they send a signal to the control panel, which then goes into alarm.
To provide adequate cover for the house it is necessary to determine what are the areas where an intruder could gain entry and secondly what are the most sensitive areas that you would most like to protect.
At the very least there should be a detector in the hallway downstairs and upstairs. If the intruder gains entry he/she will have to cross these areas in order to move around the house. It is then necessary to look at the areas of the house where the intruder may gain entry and leave again via the same route with valuables and install a PIR in these areas. These areas might be the computer in the spare room or the jewellery box in the main bedroom. These areas should also have a PIR installed.
Q. In a 3 bedroom semi-detached house the average amount of detectors required is normally 4 or 5, 3 downstairs and 1 or 2 upstairs. In a detached house this figure increases to 5 or 6 as an average.
In order to install properly you should not install more than 1 detector per alarm zone on the control panel unless a 'latching' PIR is used. This is so that in the event of an alarm or false alarm it is possible to distinguish which detector caused the control panel to go into alarm. Latching PIR's have a visual indication on the detector that it has triggered but it is necessary to install 8-core cable for these to work. They are perhaps better suited to retrofit situations where additional detectors are required on an existing installation.
Most modern control panels have 8 alarm zones so it should be within the scope of the panel to install standard non-latching PIR's. If more than 8 PIR's are required and or 1 or more of the zones is being utilised as a panic or fire detection zone it would be better to step up to a 16 zone burglar alarm panel. At this moment we do not list one on our web site but you can email or telephone us and we will be glad to provide details.
The plan shows a basic layout of a smaller house. There are 3 PIR detectors installed on the ground floor with a further PIR installed in the landing area on the top floor. There is also a door contact protecting the front and back doors.
Q. I have an old 4 zone ADE panle. I want a panle that is the same size, with or without remoter keypad that has the facility to lock out a zone after a set number of activations from that zone. Will the new ADE panles do this?
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required
Q. What are all the different types of detectors that are available?
| a).Passive infrared detector | Monitors movement within the property by means of infrared. | |||||
|
||||||
| b).Passive infrared pet immune detector | by means of either lens masking or electronic circuitry the PIR is made to ignore animals under a certain weight while still monitoring the area. | |||||
|
||||||
| c). Passive infrared quad detector | Passive infrared detectors are normally dual element meaning that both infrared elements need to be triggered before sending a signal to the control panel. A quad detector had two dual elements that all have to be triggered before sending a signal to the control panel giving a greater immunity to false alarms. | |||||
|
||||||
| d). Duel Technology detector | A PIR detector & microwave detector combined, has all the features of a normal detector with the addition of microwave detection which is not affected by temperature which makes them very effective for use in situations where there are large temperature fluctuations like conservatories. Also the microwave must be set correctly as it can monitor through walls. | |||||
|
||||||
| e). Glass break detectors | Detect the braking of all standard glass types and thickness whilst ignoring non-framed glass and other possible sources of false alarms. | |||||
|
||||||
| f). Vibration detectors | Detects the vibration of either a window being smashed or a opening being forced, again these detectors need careful installation to ensure correct operation. | |||||
| g). Magnetic contacts | The magnetic contact is used to monitor door and window openings. They work well as a device that initiates the entry timer of the alarm when entering a property. | |||||
|
||||||
Q. what are dimensions for Pyronic sterling ten polycarb end station? Can this panel lock out a zone after a set number of activations from that zone?
if you would like to contact Pyronix technical on the following telephone number 01709 700100 they will be able to advise you.
Q. Where do I install the detectors?
It is often the case in burglar alarm installation that the easiest solution is not always the best solution. PIR’s should be installed so that they are triggered by walking across the beam and not towards or away from it. They should not be placed in direct sunlight and they should not be placed where glass can refract sunlight onto them. Do not place them over fires or radiators or any other heat source. Conservatories, greenhouses and some garages should have duel technology detectors installed to cope with the temperatures in these areas. Small garages with 1 opening can normally use a quad PIR detector.
Q. What do I do about my pets?
Depending on the weight of the pet/s concerned you can install a pet immune PIR. These detectors will allow your pet/s to move around within the area monitored by the detector without setting the alarm off.
Q. i hav just installed a accenta ade gen4 alarm with led keypad but whenever i start it up and put in the default code in the spanner symbol stays on i have linked all zones out and all tampers could you help me out
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required
Q. What back up batteries do I need?
The only backup battery that you will need is the one for the control panel,
a rough size guide is as follows:
| Control panel & up to 3 PIR’s | 1.3ah battery |
| Control panel with remote keypad & up to 4 pir’s | 2.4ah battery |
| Control panel with up to 3 remote keypads & 6 pir’s | 3.4ah battery |
| Over the above quantities | 7ah battery. |
However, to work out properly the size of battery needed it is necessary to work out how much standby time is required (i.e. in the event of mains failure) and the amount of current that the system installed will require. The standby time should be at least 8 hours for Grade 1 systems and at least 15 hours for Grade 2 systems. In order to comply with EN50131-6 the standby time should be at least 12 hours for both Grade 1 and 2 systems.
The table shows the rated output currents for the standard 12v burglar alarm battery sizes.
| Battery Standby time | ||||
| 8hrs | 12hrs | 15hrs | ||
| Battery Capacity | 1.3ah | 150ma | 100ma | 80ma |
| Battery Capacity | 2.4ah | 263ma | 175ma | 140ma |
| Battery Capacity | 3.4ah | 375ma | 250ma | 200ma |
| Battery Capacity | 7.0ah | 600ma | 583ma | 467ma |
Q. I have a Honeywell ADE Gen 4 alarm fitted approx 6 months ago. The main control panel is hidden away with an accompany key fob panel near the front door. The key fob panel has just stopped working. The main panel still works if I press in the numbers but the fobs seem completely dead. Any ideas how I can fix this much appreciated - thanks
. If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required
Q. Can I install the alarm myself?
If you have some electrical experience then an alarm system should be within your scope. Sighting and setting up of the detectors should be done with some thought and taking care to read the above instructions (“ Where do I install the detectors?”). Together with the manufacturers instructions to ensure trouble free operation without false alarms.
Q. How do I choose a control panel?
All of the control panels included in our site are good quality. If you are not sure which panel to choose start with the complete alarm kits page looking for the nearest complete kit that suits your needs and then add any extra components that you require.
Q. Do I get full instructions?
Yes full manufacturers instructions are provided with all burglar alarm products including kits..
Q. Where do I provide power to the control panel?
Always ensure that you have isolated and switched off any electrical installations before you commence work. The best place to get power to the alarm control panel is directly from the consumer unit. The burglar alarm should have its own individual circuit protected by a 6a miniature circuit breaker. The cable from the 6a mcb should be 1.5mm twin & earth sheathed cable, which runs into an unswitched fused 3a spur connection unit (supplied with our kits) that then wires into the alarm control panel.
If it is not possible to wire in directly to the consumer unit then it is possible to spur off of an existing circuit, again using the spur unit provided in our kits. The cable from the existing circuit to the spur should be of the same size as the existing circuit. We would recommend the use of a spike suppressor (Our code ‘SUP’) when spurring off of an existing circuit to avoid false alarms caused by mains spikes from other equipment on the same circuit.
- Only connect the mains supply to the mains terminal block, NEVER directly to the PCB.
- ALWAYS refer to the National Wiring Regulations when conducting an installation.
- An appropriate & readily accessible disconnection device (e.g. An unswitched, fused 2a spur) MUST be provided as part of the installation.
- The disconnection device must not be fitted with flexible cord.
- Where identification of the neutral in the mains supply is NOT possible a two-pole disconnection device must be used.
- The building mains must incorporate a short-circuit back-up device.
- Use mains cable of adequate carrying capacity for the rated current (i.e. 1mm Twin & Earth 6242Y).
Q. I have had a really good experience with a Pyronix Sterling 10 alarm supplied by you some years ago. I am now in a house that needs 9 or 10 programmable zones, unfortunately the Sterling 10 has only 8. Is there a similar product to the Sterling 10 doing more zones? If there is not something similar, what would you recommend?
Q. We have a Veritas alarm which was installed in 2000. This week it has started continuous 3 beep signals coming from the outside bellbox (i.e. Beep..Beep..Beep..pause..Beep..Beep..Beep etc). Does this mean the battery needs attention (it is 11yrs old)? I can't find any information in the User Guide to help. Btw, the alarm all seems to be working OK
If you contact Texecom on the following number 01706 220460 they will be able to advise you further.
Q. hi, if possible can you send me some info on trade discounts if you do any. we dont really advertise or push alarm systems but seem to be getting asked a lot recently for equipment and have no current trade source as we do everything else we supply. Regards, Daryl Peacock StaySafe Electrical
If you would like to contact Alert Electrical on the following number 0115 8715086 9am - 4pm Monday to Friday or at support@support.alertelectrical.com our sales team will be able to advise you furthe
Q. System (9448) only sounds constant tone rather than intermittent when leaving house. How do I return it to sounding intermittent? This is in a house I acquired 4 yrs ago. According to previous owner records, system was installed on 3/8/95.
Thank you for Contacting Alert Electrical Support, if you would like to contact Scantronic technical on the following telephone number 01594 545454 they will be able to advise you.
Thank you for your enquiry.
Q. Hello, When I order Texecom Odyssey 5E Compact 109db External Sounder whit RED strobe, how many sounders I must order. And can you give me the delivery time to The Netherlands for this product. "We stock only white bellboxes with blue strobe, red strobes are only available by special order" Regards.
If you would like to contact Alert Electrical on the following number 0115 8715086 9am - 4pm Monday to Friday or at support@support.alertelectrical.com our sales team will be able to advise you further
Q. I have bought a house with a C & K Securitech alarm system but have no code to operate it. How can I put in a new code.
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required.
Q. Good morning/evening, Which module is required for Texecom Premier 24, to enable Red Care monitoring. Will the Premier Com300 Plug on Digicom suffice ?
Q. I have a 12 year old system installed (ADE Accenta Compact) with all 8 zones used on the module. I am looking to add an additional PIR into the garage, is this possible and what do I need? Regards Paul
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to give you the technical advice required.
Q. I have recently moved home and i have an optima XM6 alarm system. the panel is faulty and i would like to replace it and add extra sensors. Which panel is the best one to replace it with??
If you contact the manufacture Honeywell on the following number 01698 738570, they will be able to advise you on the most suitable panel to replace your existing system
Q. Hi there I purchased some good from you and am at a loss to find the invoice it was not in the box with the goods neither was it attached to the box I've checked my e-mails and it hasnt been sent there pls could you advise if I can download the invoice from your website I have checked but cannot seem to find any such facility the order ref is W20110507N24 Many Thanks Barbara Walker
If you would like contact the Alert Electrical on the following number 0115 8715086 9am - 4pm Monday to Friday or at support@support.alertelectrical.com they will be able to provide you with a copy invoice.
Q. hi,, i have activated the tamper spring on my scantronic 9427 panel used in conjunction with a 9448 main panel. the panel has been put back correctly and the spring is compressed tight. i have opened the 9448 and removed the 240v fuse and battery fuse but unable to cleartamper alarm light. my installer is no longer in business. is there anything else i could try inside the box or will i have to get another alarm engineer out? thanx for your advice.
If you contact the manufacture Cooper Security on the following number 01594 545454, they will be able to give you the technical advice required.
Q. What is DD243?
BSI DD 243: 2002 is a code of practice for the installation and confirmation of intruder alarm systems designed to generate confirmed alarm conditions. The document was written in response to the ACPO Security Systems Policy 2000 published by the Association of Chief Police Officers, which became effective on October 1st 2001.
It means that if you supply intruder alarm systems that require a police response, you may need to dramatically change the way you design and/or install those systems.
This applies to systems installed to BS4737, BS7042 or EN50131-1
This information was provided with permission from the 'DD243' website, click for more information.
Q. when my alarm is not on when i walk into the room the sensor picks up and beeps at the alarm.
There could be two reasons for this;
- Your smoke alarm battery is low and is beeping
- The zone of the area that is beeping on your alarm panel is set to 'chime' which needs to be changed.
Thank you for your enquiry.
Q. is is possible to buy a new keypad and also a new panel.Both for the scantronic 916.How much are they?
I believe that the Scantronic 916 is an obsolete control panel. Here is the link to the alternative hard wired control panels on our website: Scantronic burglar alarm panels
Thank you for your enquiry
Q. Do you have a direct replacement for a Scantronic 9600 keypad?
If you contact the manufacture Cooper Security on the following number 01594 545454, they will be able to give you the technical advice required.
Q. We inherited a veritas excel burglar alarm system it will not reset with pin number number not registering on screen please advise
Please contact Texecom on 01706 220460. They should be able to help you with your enquiry
Q. How many years do you anticipate the following parts to last and what are the likely cost/s to replace either/both? 8136EUR control panel 931 keypad
Good Morning
If you would like to contact Scantronic technical on the following telephone number 01594 545454 they will be able to advise you
Q. Hi I have recently installed a Veritas 8 alarm-do I need different type of PIR sensor in my conservatory as it going off intermittanly
A conservatory is a hostile environment for a PIR becasue of heat causing alot of thermal air movement. Therefore we recommend two types of detector for conservatories:
| c). Passive infrared quad detector | Passive infrared detectors are normally dual element meaning that both infrared elements need to be triggered before sending a signal to the control panel. A quad detector had two dual elements that all have to be triggered before sending a signal to the control panel giving a greater immunity to false alarms. | |||||
|
||||||
| d). Duel Technology detector | A PIR detector & microwave detector combined, has all the features of a normal detector with the addition of microwave detection which is not affected by temperature which makes them very effective for use in situations where there are large temperature fluctuations like conservatories. Also the microwave must be set correctly as it can monitor through walls. | |||||
|
||||||
Our PIR category with a choice of manufacturers can be found here Burglar Alarm PIR & Detectors
Thank you for your enquiry.
Q. Can you supply me with user manuals as I have only recently moved into the house and the person I bought it off of has not left me any instructions.
We get a number of requests for replacement manuals. There are two types of manual for a burglar alarm control panel. One is the 'User Guide' which will give the user of the system information on how to get the most out of the alarm system. Information like full setting, part setting, omitting a zone will be in here. The other is the 'Engineer Manual' which gives information on installing the system, programming the panel, re-storing the panel to factory defaults etc.
We can supply 'User Guides', you will find these below stored in PDF format, you will need an Adobe Acrobat Reader to download these.
We cannot supply 'Engineer Manuals'. There are security implications to supplying these manuals, please contact the manufacturer of your intruder alarm panel for the information that you require. If you have lost the user code for your control panel then it may be necessary to contact an approved local security alarm installation company who will come and reset your control panel for you.
User Manuals
Texecom
Pyronix
| Matrix 832+ | 1 434 KB |
| Matrix 6 | 1 243KB |
| Paragon Super II | 388KB |
| Paragon Plus | 461KB |
|
536KB |
|
| Sterling 10 LED |
304K |
| Sterling 10 ICON/Compact | 714KB |
| Vocaliser User Manual | 23KB |
Scantronic
| User guides for all Scantronic control panels |
Contact Details
Pyronix: www.pyronix.com
Texecom: www.texe.com
Lynteck: www.lynteck.co.uk (Melcom control panels)
Honeywell: www.getintellisense.co.uk (Securit control panels)
Scantronic: www.scantronic.co.uk
Q. Is there a combined fire/ burglar alarm on the market?
Depending on how many smoke alarms you require most of the burglar alarm panels have the facility to add smoke and heat detectors to the panel. For example the Texecom Premier range are compatible with 12v 2 and 4 wire smoke and heat detectors. Texecom also produce a comprehensive range of 12v smoke and heat detectors to give warning via the burglar alarm system should a fire break out on the property.
Q. 9448 Cost 31.01 euro. What is the delivery charge to Southern Ireland ?
Please see below for the information, if you wish to change or add other items the carriage charge is shown at the checkout.
| Quantity | Total (exc. VAT) | Total (inc. VAT) | |||
|---|---|---|---|---|---|
| Delete | Scantronic 9448EUR 7 Zone Panel | Less Qty.More Qty. | €31.01 | €36.43 |
| Sub Total (exc. VAT) | €31.01 |
| Sub Total (inc. VAT) | €36.43 |
| Delivery | €13.91 |
| Total (inc. VAT) | €50.34 |

Thank you for your enquiry.
This delivery charge is correct for your location.
Q. How long does the delivery take to come through?
Good Morning
If the item or items you wish to order are in stock and ordered before 2pm then delivery would be next day by DHL/Yodel. Please see our delivery section on the website.
Thank you for your enquiry.
Kind Regards
Customer Services
Q. Hi, we have a 9448+style alarm which we got in 2003, it has,nt been working for 2 years. Engineer came to set it back up but seemingly needs a user code number to do this, can you help?. Also battery is dead, which one is suitable for alarm?. Regards, CRN.
Hi there.
The engineer needs to reset the control panel back to factory settings, any professional alarm engineer should know how to do this. The replacement battery is a 2.4ah 12v.
Thank you for your enquiry.
Q. If I purchase the Scantronic i-ON40, plus the additional items to make up a system and I am fitting it myself, do I receive the system reset code as I am the administrator for my own system?
Good Afternoon
you will receive an engineer code for this panel, with this you can create your own access code of your choice
Q. What is a suitable modern DIY replacement for an old (20 years plus) and damaged "Honeywell ADE Optima XM" intruder alarm panel ?
Good Morning
A good replacement for the Optima XM would Be the Honeywell/ADE 8EP396A and AB21 battery to suit.
Kind Regards
Customers Services
Q. I have scopetronic a home guard alarm system - it had a external bell box with two wires (red/green) going to two wires (red/black) of a siren and two wires (yellow/blue) going to two wires (red/black) of a strobe. I have replaced the box with a Pyronix Belle but the strobe works but the siren does not sound when the alarm is activated. I connected b+ to red and ba to green Could I have blown a fuse or is there another explanation? Thanks
Good Afternoon
After Spending sometime looking for information on this product unfortunately the information i have found does not help with this question.
The best thing i can advise on this would be if you would like to contact Pyronix technical on the following telephone number 01709 700100 they will be able to advise you
Many Thanks
Nathan Swann
Q. I have a house that's 20+ years old and the house alarm was installed from new. It has detector blocks on downstairs windows and front & rear entry doors. It also has a motion detector in the main living area and external alarm bell. The alarm control box uses a key to set either 'all windows and doors' or those plus the motion detector. The make is Securitech Minisec/2. It has been giving me false alarm problems for several years, usually corrected by head scratching by an engineer, then installing a new back up battery. However, now this doesn't seem to remedy the problem because the alarm will not always reset, so it cannot be used. I am reluctant to install a new wireless, etc. system at present because my current one (when working) protects a wider range of points in the house. Does anyone have any ideas as to how to remedy the problem. I've had several trades people to look at the problem recently but again after installing a new battery the problem has not been resolved.
Good Morning Rob
After reading your email and looking through the Internet on this panel i can see allot of people say they have the same problems with this panel
as the panel is very old and not something i have dealt with before it would be difficult for me to suggest anything but a replacement system.
for a system to last more than 15years is extremely rare
if you would like further information on new alarms systems please contact me
Many thanks
Nathan Swann
Q. To: Nathan Swann Hi, thanks for your reply today, to my query about the problem with my 20+ year old Securitech Minisec/2 burglar alarm system. It may be that it's on it's last legs now as you say. You mentioned that you may have ideas on suitable replacements for my system, if so I would be grateful as to any recommendations you may have and if possible any ideas about what sort of cost they may be. Thanks Rob.
Good Morning Rob
I would suggest a kit for this as the whole system would need to be replaced
I would suggest KIT1 as i feel this would meet your requirements
Q. I have just moved in to a new house with a texecom veritas 8 compact burglar alarm. The precious owner told me the code was 1963 however i am unable to unset the alam with this code. Currently I am having to have the downstairs lights switch fuses turned off in the fuse box as everytime I turn this on the alarm goes off. Please help!
Good Morning Lee
Unfortunately without the engineers code it would be imposable to change the code on this alarm panel
also the faults you seems to be getting suggest the maybe a faulty on the unit and may have to be replaced
if this is the case i would suggest the Texecom V8C as a suitable panel for your needs
Many Thanks
Nathan Swann
Q. We have an Scantronic 9448 system, but the key panel has worn out and hardly responds, how do we fix this, is it a case to buy just the front panel and is it easy to install as I heard opening the box will activate the alarm system. Thank you
Good Afternoon
Unfortunately Scantronic do not supply replacement keys for this panel
we would have to advise on a purchase of a new panel on this occasion
Q. Hi I have a veritas 8 panel with remote keypad.When we were away the system alarmed but after ringing for so long would shut off then re start.aparantly this went on all night.Any ideas?
Good Afternoon
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. I have a prospective customer who wants an alarm for four seperate adjacent workshops in a small terrace. Each workshop has a seperate door and there is no door between them. He wants to be able to go into each workshop without having to unset a central alarm. He has some people who have access to one workshop but not the others. Is there a unit which would allow four seperate keypads to set/unset each of the four zones, each effectivly being an entry/exit zone. It may be acceptable if the whole system was disarmed /armed each time. Thanks in advance. Kevin
If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. I have just purchased a house which is 2 yr old. It has a Texecom Veritas TEXRKP keypad with 8 zones. Can you e-mail me with a set of user intructions please.
Click the following link and you will find the user manual that you are looking for: LINK
Q. If I am installing an alarm system myself, do I need to contact the manufacturer or an alarm engineer at any time during the intallation to start it properly?
Q. I was looking at your KIT1 alarm system, and wondered whether these are supplied to you or you actually make them up yourself?
Yes we do make the kits up ourselves. It is possible for you to choose the individual parts from our site to make up the kit that you need otherwise please email nott@alertelectrical and we will be pleased to help you with your selection.
Q. I have had a vertas alarm for approximately 10 years, it has now developed a fault. when the mains power is turned of (power cut) the outside alarm box "beeps" for approximately 8-10 Minutes. Once power is restored the the alarm panel shows each zone as red then the internal alarm sounds, this can only be silenced by turning the mains off or entering the engineer code. Subsequently the I then have to re-enter the entry code. Can you advise me, is this the battery which is housed in the main unit? or are there other areas that I should be checking (battery). I have both installation manuals however I dont appear to have any information on the vertias model. Thanks
Thank you for contacting Alert Electrical . If you contact Texecom on the following number 01706 220460 they will be able to advise you further
Q. Castle Care Tech User Guides
Castle Care Tech User Guides
| Link to product on alertelectrical.com | User Guide |
| Castle Care Tech Euro Mini Control Panel | Castle Care Tech Euro Mini Control Panel |
| Castle Care Tech Euro 46 Control Panel | Castle Care Tech Euro 46 Control Panel |
| Castle Care Tech Euro 76, 162 and 280 Control Panel | Castle Care Tech Euro 76, 162 and 280 Control Panel |