Tools For Electricians -> Electricians Test Equipment -> Pat Testers & Calibration Checkers -> Seaward Prime Test 300 PAT Tester
Dont Let Your PAT Tester Slow You Down
Battery Powered. Move faster between tests.
A battery powered PAT tester means that you spend less time plugging and unplugging your tester and more time testing, and gives you the flexibility to test when and where it is right for you
Wireless Working. Less leads, more time.Free yourself of the cables and leads you need to run your accessories and free your time to carry out more testing. Hand-Held. Smaller and easier to use.Move faster before, during and after test, with this easy to handle and use ‘comprehensive’ PAT tester. PAT testing and beyond, PrimeTest 300 is The Complete Safety Tester Test the Appliance. Test the Circuit. Record asset locations and nonelectrical test results Features • Wireless data transfer system using Bluetooth technology • Battery driven for mains free working • Intuitive and fast user interface • Manual and automatic test modes • User definable and configurable test sequences • Graphic display • Full keypad • Large memory for storing results and test programs • Download / Upload to software • Insert your own logo and details on the tag • Brain cell capability Technical Specification Earth Continuity Output Current (Load 2 :)Ω +/- 200mA DC Test Voltage (o/c): > 4VDC Test Duration: Programmable within a maximum limit Measuring Range: 0.01 - 19.99Ω Operating Error: +/-5% + 2 counts Measurement Resolution: 0.01Ω Pass Value: User defined Insulation Test Test Voltages: 500VDC @ 1mA nominal Test current: >1mA into 500kΩ; < 2mA into s/c Test Duration: Programmable within a maximum limit Measurement Range: 0.10 MΩ - 40MΩ Operating Error: +/-5% +2 digits Measurement Resolution: 0.01MΩ (Max) Pass Value: User defined Differential Leakage Test Voltage: 230V +10%, -15% Maximum Load current: 13Arms Test Duration: Programmable within a maximum limit Measurement Range: 0.25 - 19.99mA Measurement Resolution: 0.01mA Operating Error: +/-5% of reading +/- 2 digits Pass Value: User defined Touch Leakage Test Voltage: 230V +10%, -15% Maximum load current: 13Arms Test Duration: Programmable within a maximum limit Measurement Range: 0.10 - 3.50mA Measurement Resolution: 0.01mA Operating Error: +/- 10% of reading +/- 2 digits Pass Value: User defined RCD Test Test Voltage: 230V +10%, -15% Test Current: 30mA rms sinusoidal Test Current Accuracy: +10, -0% Test Current Phase: 0°/180° auto switched on alternate Test Duration: 2000 ms maximum if RCD does not trip Measuring Range: 10ms - 2000ms Operating Error: ±10% Measurement Resolution: 1ms Earth Loop Resistance Test Test Voltage: 230V +10%, -15% Test Current: Such that it will not trip a 30mA RCD Measuring Range: 1W - 199W Operating Error: ±10% +2 digits Measurement Resolution: 0.1W (Max) Lead Test Test voltage: 9 VDC Test Duration: 2s Test: Live / Neutral Checks for o/c, s/c and crossed Power Socket Test Input voltage range: 230V +10%, -15% AC Indicators: phase to earth voltage phase to neutral voltage neutral to earth