Scantronic i-RK01 Wireless Radio Keypad
The Scantronic I-RK01 Radio Keypad is designed to work with the Scantronic i-ON16, i-ON40 and i-ON160EX control panels.
View Info
The Scantronic i-ON160EX is the main control unit for a 10 zone expandable hybrid, wired or wirefree burglar alarm system to 160 zones that extends the Scantronic i-ON range
| Code | I-ON160EX |
| Stock | 4 days estimated delivery |
| Reviews | No reviews yet |
Price: £194.73
| Option | Price | Qty. | |
|---|---|---|---|
| Scantronic I-ON160EX 10 Zone Expandable To 160 Zones Security System (I-ON160EX) (4 days estimated delivery) |
£194.73 £233.68 inc. VAT |
Less Qty.More Qty. | Add to Cart |




The Scantronic i-on160EX is the main control unit for an expandable hybrid, wired or wirefree burglar alarm system that extends the i-on range to network expandable systems for more complex installations where a much more flexible solution is required. One i-on160EX control unit can operate up to 160 zones by using expanders sharing a single bus cable. Different types of expander allow either wired or wirefree detectors in the same system. The bus cable also allows the installer to connect keypads or extra power supplies wherever they are needed.
The system uses the same keypad, radio peripherals and the 760ES radio bell as the i-on16 and i-on40 and the same communicators as the i-on40.
The expandable i-on platform is a completely new design and offers a range of clear benefits to installers these include:
A coated steel case houses the control unit’s pcb, power supply and up to two 17A backup batteries. The case is designed for vertical mounting on a wall, and provides three fixing points. The case can be butted up to side walls or a ceiling without blocking the lid. The lid is fixed by a single screw, and can be hung from the case back when open.
The control unit provides connections for up to 10 wired zones. These zones can be either all Closed Circuit (CC) or all Fully Supervised Loop (FSL). The Installer can select the zone wiring type during initial commissioning, or at any time after. The Installer can make the wiring type of the expanders either CC or FSL, independently of the wiring type of zones on the control unit.
The control unit provides connectors for four programmable outputs which can be used to control external equipment (two transistor outputs and two voltage free changeover contacts). In addition there are dedicated external bell and strobe outputs. Expanders also provide connectors for additional external sounders and outputs.
A separate set of 16 pins on the control unit pcb provide programmable outputs designed to control a separate digital communicator.
If required the Installer can connect one 16Ohm extension loudspeaker to increase the audibility of setting and unsetting tones. Each expander also provides connectors for a 16Ohm extension loudspeakers
The i-on160EX uses i-kp01 keypads with keypad firmware version 2 and above. The keypad has a two line by 20 character backlit LCD display and a built in proximity tag (prox tag) reader. All keypads connect directly to the system bus.
Users can set and unset the system or partitions from the keypad, either by keying-in access codes or presenting a prox tag.
The EXP-W10 wired expander provides connections for either 10 FSL zones or five CCL zones, one loudspeaker and four wired programmable outputs
The radio expanders provide channels for either 10 radio detectors (EXP-R10) or 30 radio detectors (EXP-R30). In addition each radio expander provides channels for: two radio keypads, two external radio sounders and two Wireless Accessory Modules (WAMs). Each radio expander also provides wired connections for a Loudspeaker.
The i-on160EX provides a socket for an add-on communication module. The available modules are:
The USB (Universal Serial Bus) and Ethernet ports on the control unit pcb provide two different methods of connecting an external PC (personal computer) to the control unit.
The USB port allows an Installer to program the control unit through a local connection by USB cable from PC to control unit.
The Ethernet port also allows a local connection to a PC. The Ethernet connection is designed to allow an Installer to program the control unit through a series of web pages presented by a built-in web server running on the control unit.
The i-on160EX offers two basic ways of behaving as an alarm system.
In Part Set Mode the i-on160EX can set in either Full set or three varieties of Part Set.
In Partition Mode the i-on160EX provides the equivalent of 20, smaller, independent alarm systems. Each system is a “Partition” of the i-on160EX. Each zone can belong to more than one Partition. Each Partition can have a Full Set level and one Part Set level. During programming the installer can allocate keypads, sounders or outputs to any of the partitions.
During initial power up (and if you reset a system to factory defaults) the system provides an opportunity for you to set various system options in one step in order to program the system for either EN50131-1:2009 Grade 2 or EN50131-1:2009 Grade 3. PD6662.2010 and BS8243.2010 Approval
You can override any of the settings by selecting individual options in other parts of the Installer Menu. Note that if you do so then the system may no longer comply with the selected Grade.
As an installer you can program the system in any of three separate ways:
a) From the keypad.
b) From a PC or laptop connected to the control unit via Ethernet cable, and using a web browser (IE 8 recommended).
c) From a PC or laptop connected to the control unit either over the PSTN or via the USB port, using i-on Downloader software (available soon).
Further Information
Compatible Products
| AB7 | 7ah 12v back up battery |
| XCELR | Radio PIR |
| XCELRPT | Pet tolerant Radio PIR |
| XCELW | Hard wired PIR |
| XCELWPT | Pet tolerant wired PIR |
| EXP-W10 | Wired 10 zone expander , utilises the new i-on bus system |
| EXP-R10 | Radio 10 zone expander, utilises the new i-on bus system |
| EXP-R30 | Radio 30 zone expander, utilises the new i-on bus system |
| i-RC01 | 4 relay board converts transistorised output to relays. |
| I-KP01 | Wired keypad for the i-ON range. Up to two can be installed on the Scantronic i-ON16. Includes prox reader and two button panic attack |
| I-RK01 | Radio keypad for the i-ON range. Up to two can be installed on the Scantronic i-ON16. Includes prox reader and two button panic attack |
| I-SD02 | Plug-in SD/comms module. Connect to central station or send voice messages to phone numbers of your choice |
| I-GSM02 | GSM autodialler |
| Telephone auto-dialler for the i-ON40 and i-ON160EX control units | |
| I-FB01 | Remote control for the i-ON16. Allows setting, part-set and un-set. |
| 760ES | External radio sounder complete with cover. Designed specifically for the i-ON range. |
| 760DS | Dummy sounder complete with cover. |
| 710rEUR-00 | Radio small profile hand held dual action PA transmitter. |
| 720rEUR-00 | Optical smoke detector. Uses 9v battery |
| 734rEUR-01 | Lithium powered White contact TX |
| 734rEUR-06 | Lithium powered Brown contact TX |
| 738rEUR-00 | White Spyder shock/vibration sensor |
| 738rEUR-04 | Brown Spyder shock/vibration sensor |
| 770REUR-00 | Wireless Accessory Module WAM |
| 771REUR-00 | Wireless Information Module |
Specification
| Compliance | PD6662:2004 and EN50131-1:2004 Grade 2, Environmental class 2, DD243:2004 |
| Zones | 24 radio, 16 wired |
| Panel | 40 zone hybrid end station with remote keypad |
| Keypads | Accepts 4 wired and 4 wireless keypads |
| Proximity Reader | The i-on40 keypads, both wired and wireless, contain a proximity reader as standard |
| Display | Large blue backlit LCD display, full feature plain text, 2 lines, 20 character per line |
| Setting options | A = full set, B, C and D = part set or 4 independent partitions |
| Event Log | 1000 event log with date and time stamped |
| Codes | 50 user codes, 4 digit PIN number, proximity or remote control |
| Internal Sounder | 1 x 16 ohm internal sounder |
| Outputs | 2 relay and 14 transistorised (i-rc01 optional relay board available ) |
| Remote Communications |
Speech dialler, 8 channel fast format and contact ID |
| Power Supply | Conforms to EN50131-6 Type A power supply, rated power output 1.5A of which 850mA is available for auxiliary power |
| Battery | Accepts a 12v standby battery up to 7Ah rechargeable lead acid, gel type |
| Dimensions | End station: 384 x 245 x 94mm Keypad: 115 x 156 x 34mm |
| Weight | End station: 1.1kg Keypad: 0.32kg |
| Temperature Range | Environmental class 2 -10°C to 55°C @ 75% RH |