Alert Electrical Limited

Menvier 40 Security Alarm Control Panel Grade 2 Or 3

Menvier 10 zone control panel, expandable to 40 wired or wireless zones. Ideal for smaller PD6662:2010 grade 2 or 3 installations

Read More

CodeMENVIER40

Price: £131.89


Menvier 40 Security Alarm Control Panel Grade 2 Or 3
 Click to Enlarge
Option PriceQty. 
Menvier 40 Security Alarm Control Panel Grade 2 Or 3 (MENVIER40) £131.89
£158.27 inc. VAT
Less Qty.More Qty. Add to Cart
Download Data Sheet
Brand

Menvier 40 Security Alarm Control Panel Grade 2 Or 3

This product requires either a wired or wireless keypad, please see below.

Menvier 10 zone control panel, expandable to 40 wired or wireless zones.  Ideal for smaller PD6662:2010 grade 2 or 3 installations.  The system is controllable via a pin number, proximity fob or remote control.  It can have 100 different users.  For easy installation the Menvier 40 is supplied with a steel end station for first fix and easy clip in separate PCB.

The Menvier 40 accepts the Cooper range of secure narrowband 868Mhz radio wireless products. The PCB has onboard Ethernet providing a web browser capability plus local networking capability.  It can take up to an 18an back up battery.

The control unit is approved to be used as part of a Security Grade 3 system.  it is also approved to be used as part of a Security Grade 2 System.  If wireless devices are used this will limit the security approval to Grade 2 in the ward that the wireless devices are used.

Features

Decimal expansion
All panels have 10 wired zones on the end-station and expand in 10 zone blocks making it easier to identify expanders and zone locations.

Performance bus technology
The Menvier40 bus can accommodate 20 bus devices and the Menvier100 and Menvier300 can accommodate 45 devices. This gives significantly increased flexibility and system control.

Semi-automatic addressing
Devices are addressed by the push of a button. This ensures two devices will never be given the same address and saves hours of onsite and diagnostic time.

Bus device locator
Enables the fast and easy location of bus-mounted devices, saving significant time on service and maintenance visits.

Dynamic engineer session
Allows the transfer of the engineer session around the system’s keypads to speed up installation.

Compatibility
All Menvier panels are compatible with a wide range of Cooper Security intruder peripherals see pages 8-10 for details.

Web browser interface
All the new Menvier panels have a built in web server and Ethernet connection. This enables local configuration through a web browser with all the convenience of the configuration software and profile held on the panel. It also enables local network connection of panels for onsite monitoring and building services integration.

menvier40tdThis product requires either a wired or wireless keypad, please see below.

Product name Menvier40
Product Description 40 zone hybrid endstation with remote keypads.
Manufacturer Cooper Security Ltd.
Environmental Class II.
Operating temperature Tested -10 to +55°C.
Humidity 0 to 93% RH, non-condensing.
Case material Steel.

Dimensions:

Control unit 320 x 400 x 100, mm HxWxD.
Keypad 115 x 156 x 30, mm HxWxD


Weight:

Control unit 4.9 kg (without stand-by batteries).
Keypad 0.26 kg


Capacities

Zones 40 max (with expanders)
Outputs

16 plug-by communicator outputs on control unit, plus 
40 max for the rest of the system, comprising: 
3 wired on control unit (two transistor and one relay) 4 transistor based on each wired expander 8 radio outputs on each 768/769 2 radio outputs on each 762

Expanders and Wired Keypads 20 max devices (see note 1)
Radio Keypads 5 max (two per radio expander)
External Radio Sirens 5 max (two per radio expander)
WAMs 5 max (two per radio expander, repeater mode only)
Loudspeakers 1 on control unit, one per expander
Plug on communication modules One
Other ports 1 x USB, 1 x Ethernet
Wards 5 (see note 2)

 

Calendar Set Timers 5 max
Log capacity

Up to 1,000 events: 750 mandatory events, 250 non-mandatory. Stored in EEPROM memory, available for at least 10 years without power.

Internal Clock ±10 minutes over one year (depending on the accuracy of the mains supply frequency).
User Codes 100 (plus installer code)
Remote controls 100 (one per user)
Hold Up Alarms 100 (one per user)
Proximity tags 100 (one per user)
Shunt Groups 1
Custom Outputs 5


Notes:
1. Wired keypads, wired zone expanders, and radio zone expanders are all bus devices. You can connect any combination of these devices to the bus.
2. The system can be used as EITHER a Ward Based System OR a part setting system. When used as a part setting system there are four setting levels available: Full Set and Part Sets B, C and D.

Security

Security Grade Grade 2 or 3
Radio detector differs 16,777,214 (2^24-2).
Radio Supervision Programmable.
Number of access codes 100 plus one installer
Access code differs 10,000 differs with 4 digit codes. 1,000,000 differs with six digit codes. All digits may be any number 0 to 9.
Code blocking Blocked for 90s after 10 incorrect codes in series.
Proximity tag differs 4,294,967,296 (2^32)

 

Power Supply

This product complies with the requirements of EN50131-6 Type A power supply at Grade 3 and environmental class 2.

Power supply type A
Mains power supply requirements 230VAC +10% / -15%, 350mA max, 50Hz.
Total power supply capacity: 1.5A (of which 750mA is used for battery recharge and 750mA is available for powering the system).
12V Aux supply*: 500mA max
12V Bell supply 500mA max
Comms power supply*: 400mA max
12V Expander Bus*: 400mA max
LS connectors 280mA in alarm.

*Note: The ratings given here represent the maximum current that can be drawn before triggering over-current protection.

EN50131-6 ratings

CIE power requirement: 120mA min. 200mA max
i-kp01 power requirement: 30mA (backlight off) 45mA/65mA (backlight norm/bright) 60mA in alarm
Wired Expander requirement 20mA max quiescent. 300mA in alarm if sounder connected.
Radio Expander requirement 40mA max quiescent 320mA in alarm if sounder connected.
Battery charging requirement: 750mA per battery (recharge within 24 hrs)
Plug-on Communicator power requirement: 20mA quiescent
50mA max
Plug-by Communicator pins require: 3mA each when active.
10 FSL zones 20mA
5 CCL zones 30mA
12V Bus output voltage range : 10±0.5V to 13.8V
12V Aux output voltage range: 10±0.5V to 13.8V
12V Bell output voltage range 10±0.5V to 13.8V
14.4V output voltage range: 10±0.5V to 14.7V
Max p-to-p ripple voltage: 0.5V
Standby Battery: 12V, 17Ah sealed lead acid, 1 off (not supplied).
°Low battery° fault at: < 12V
Aux power output fault at: < 9V
Deep discharge protection at: 10±0.5V
Overvoltage protection trigger voltage 15.8±1.0V

 

Electromagnetic Compatibility

Immunity Conforms to EN50130-4.
Emissions Conforms to EN61000-6-3.

 

Outputs

Panel: O/P 1  Voltage free, single pole relay contacts rated 24VDC @ 1A.
Panel: O/P 2 - 3 Open collector transistor, +12VDC when inactive, 0V when active. 500mA max.
Plug-by O/P 1-16 Open collector transistor +12VDC when inactive, 0V when active, 50mA max.
LS 1 (loudspeaker) Min impedance 16 Ohm per output, current consumption = 280mA in alarm.
Expander: Outputs Open collector transistor, +12VDC when inactive, 0V when active. 500mA max. Note: The current is limited by the amount available from the power supply driving the expander.

 

Sounder Volume Levels (at 1m)

i-kp01 (at max volume) 70dB
Expander sounders 70dB
Expander 16 Ohm loudspeaker 93dB

 

Fuses The control unit has a replaceable T250mA mains fuse.

Electrical Safety Conforms to EN60950-1.

Other

If you wish to connect the Menvier40 control unit to a PC using either the Ethernet or the USB port then make sure that the cables have the following specifications:

Ethernet Cat5e patch cable, RJ45 male plugs at each end, suitable for 10/100Base-T.
USB Mini-B plug for control unit end, USB-A for PC end. Max length 3m.

 

Radio Expander and Keypads

Radio Operating frequency 868.6625MHz Narrowband.

 

EN 300 220-3.
  EN 300 330-2
Transmitter range The range of the transmitters compatible with this control unit depends on the environment in which they are installed. As a guideline, most transmitters will work up 200m range in free space conditions.

 

Compliance Statements

The Menvier40 is compliant with EN50130-5 environmental class II.
The Menvier40 is suitable for use in systems designed to comply with PD 6662: 2010 at grade 3.
When installed correctly the Menvier40 is capable of compliance with EN50131 at Grade 3.
To maintain Grade 3 the Menvier40 must be fitted with a communicator of level ATS4 or above.
When fitted with radio devices the Menvier40 is capable of compliance with EN50131 at Grade 2.
The i-sd02 is compliant with EN50136-1 as an ATS2 communicator.
The i-sd02 may be used as a supplementary communicator at Grade 3.
At Grade 2 the i-sd02 provides a compliant communicator for the Menvier40 provided that:
a) It is installed in accordance with the installation instructions.
b) The connected PSTN is functioning normally.

When fitted with an i-sd02 this product provides options A, B and C at Grade 2 as noted in Table 10 of EN50131-1:2006+A1:2009.
If the installer selects a non-compliant configuration then they must remove or adjust compliance labelling
Third party testing carried out by Anpi.

 

Panel

Menvier40

Menvier100

Menvier300

PD6662:2010 Grade

2 or 3

2 or 3

2 or 3

BS8243

Yes

Yes

Yes

Maximum Zones

40

100

300

Users

100

250

500

Partitions / Wards

5

10

20

Common Area

Yes

Yes

Yes

Part Sets

3

3

3

On board wired zones

10

10

10

Batteries

1 x 17Ah

1 x 17Ah

2 x 17Ah

Networks

1

1

1

Maximum number Network Devices

20

45

45

No of radio keypads

5

10

20

Panel Relay Outputs

1

1

2

Programmable Panel Transistor Outputs

2

2

2

Maximum number of non plug by programmable outputs

40

100

300

Plugby outputs

16

16

16

Built-in Ethernet port

Yes

Yes

Yes

External Radio Sounders

5

10

20

Number of WAM’s

5

10

20

On Board Loudspeaker Ports

1

1

2

Comms Modules ports

1

1

1

Power Available

1.5A

1.5A

3A

Aux Power Available

750mA

750mA

1.5A

Built in digicom

Yes

Yes

No

Mandatory log events

750

1,000

1,500

Non Mandatory log events

250

250

500

End Station (H x W x D)

320mm x 400mm x101mm

320mm x 400mm x101mm

427mm x 400mm x 101mm

Calendar Timers

5

10

20

Custom Outputs

5

5

10

Product Categories

Alarms and CCTV

All enquiries please contact via live chat 9am - 4pm Monday to Friday support@support.alertelectrical.com please include your order number (Starts W201..)

© Copyright 2014 Alert Electrical Limited. Unit 2/3 Clarendon Court | Manners Industrial Estate | Ilkeston | Derbyshire | DE7 8EFTop