Scantronic i-RK01 Wireless Radio Keypad
The Scantronic I-RK01 Radio Keypad is designed to work with the Scantronic i-ON16, i-ON40 and i-ON160EX control panels.
View Info
The Scantronic i-ON30EX is the main control unit for an expandable 10 zone hybrid, wired or wirefree burglar alarm system up to 30 zones. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD
| Code | I-ON30EXD |
| Stock | 1 in stock |
| Reviews | No reviews yet |
Prices from: £75.95
| Option | Price | Qty. | |
|---|---|---|---|
| Scantronic I-ON30EXD Includes a plug on Digicom (I-ON30EXD) (1 in stock) |
£88.64 £106.37 inc. VAT |
Less Qty.More Qty. | Add to Cart |
| Scantronic I-ON30EX 10 Zone Expandable To 30 Zones Security System (I-ON30EX) (4 days estimated delivery) |
£75.95 £91.14 inc. VAT |
Less Qty.More Qty. | Add to Cart |



The i-on30EX is a 10 zone control panel which expands up to 30 zones using either a wired expander EXP-W10 or a radio expander (EXP-R10). The i-on30EX has a plug on footprint which will allow the connection of any i-on communicator. The i-on30EX will support a 7Ah battery. The i-on30EX supports semi automatic addressing and the expander location system. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD please see below.
The i-on30EXD is a 10 zone control panel which expands up to 30 zones using either a wired expander EXP-W10 or a radio expander (EXP-R10). The i-on30EXD has a plug on footprint which will allow the connection of any i-on communicator as well as a built in multi-format digital communicator. The i-on30EX will support a 7Ah battery. The i-on30EXD supports semi automatic addressing and the expander location system. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD please see below.
The expandable i-on platform offers a range of clear benefits to installers these include:
A coated steel case houses the control unit’s pcb, power supply and up to two 17A backup batteries. The case is designed for vertical mounting on a wall, and provides three fixing points. The case can be butted up to side walls or a ceiling without blocking the lid. The lid is fixed by a single screw, and can be hung from the case back when open.
The control unit provides connections for up to 10 wired zones. These zones can be either all Closed Circuit (CC) or all Fully Supervised Loop (FSL). The Installer can select the zone wiring type during initial commissioning, or at any time after. The Installer can make the wiring type of the expanders either CC or FSL, independently of the wiring type of zones on the control unit.
The control unit provides connectors for four programmable outputs which can be used to control external equipment (two transistor outputs and two voltage free changeover contacts). In addition there are dedicated external bell and strobe outputs. Expanders also provide connectors for additional external sounders and outputs.
A separate set of 16 pins on the control unit pcb provide programmable outputs designed to control a separate digital communicator.
If required the Installer can connect one 16Ohm extension loudspeaker to increase the audibility of setting and unsetting tones. Each expander also provides connectors for a 16Ohm extension loudspeakers
The i-on30EX uses i-kp01 keypads with keypad firmware version 2 and above. The keypad has a two line by 20 character backlit LCD display and a built in proximity tag (prox tag) reader. All keypads connect directly to the system bus.
Users can set and unset the system or partitions from the keypad, either by keying-in access codes or presenting a prox tag.
The EXP-W10 wired expander provides connections for either 10 FSL zones or five CCL zones, one loudspeaker and four wired programmable outputs
The radio expanders provide channels for either 10 radio detectors (EXP-R10) or 30 radio detectors (EXP-R30). In addition each radio expander provides channels for: two radio keypads, two external radio sounders and two Wireless Accessory Modules (WAMs). Each radio expander also provides wired connections for a Loudspeaker.
During initial power up (and if you reset a system to factory defaults) the system provides an opportunity for you to set various system options in one step in order to program the system for either EN50131-1:2009 Grade 2. PD6662.2010 and BS8243.2010 Approval
You can override any of the settings by selecting individual options in other parts of the Installer Menu. Note that if you do so then the system may no longer comply with the Grade.
As an installer you can program the system in any of three separate ways:
a) From the keypad.
b) From a PC or laptop connected to the control unit via Ethernet cable, and using a web browser (IE 8 recommended).
c) From a PC or laptop connected to the control unit either over the PSTN or via the USB port, using i-on Downloader software (available soon).
Compatible Products
| AB7 | 7ah 12v back up battery |
| XCELR | Radio PIR |
| XCELRPT | Pet tolerant Radio PIR |
| XCELW | Hard wired PIR |
| XCELWPT | Pet tolerant wired PIR |
| EXP-W10 | Wired 10 zone expander , utilises the new i-on bus system |
| EXP-R10 | Radio 10 zone expander, utilises the new i-on bus system |
| EXP-R30 | Radio 30 zone expander, utilises the new i-on bus system |
| i-RC01 | 4 relay board converts transistorised output to relays. |
| I-KP01 | Wired keypad for the i-ON range. Up to two can be installed on the Scantronic i-ON16. Includes prox reader and two button panic attack |
| I-RK01 | Radio keypad for the i-ON range. Up to two can be installed on the Scantronic i-ON16. Includes prox reader and two button panic attack |
| I-SD02 | Plug-in SD/comms module. Connect to central station or send voice messages to phone numbers of your choice |
| I-GSM02 | GSM autodialler |
| Telephone auto-dialler for the i-ON40 and i-ON160EX control units | |
| I-FB01 | Remote control for the i-ON16. Allows setting, part-set and un-set. |
| 760ES | External radio sounder complete with cover. Designed specifically for the i-ON range. |
| 760DS | Dummy sounder complete with cover. |
| 710rEUR-00 | Radio small profile hand held dual action PA transmitter. |
| 720rEUR-00 | Optical smoke detector. Uses 9v battery |
| 734rEUR-01 | Lithium powered White contact TX |
| 734rEUR-06 | Lithium powered Brown contact TX |
| 738rEUR-00 | White Spyder shock/vibration sensor |
| 738rEUR-04 | Brown Spyder shock/vibration sensor |
| 770REUR-00 | Wireless Accessory Module WAM |
| 771REUR-00 | Wireless Information Module |
Please click this link for Scantronic user manuals
For further information on the Scantronic i-ON wireless burglar alarm equipment please see Scantronic i-ON range from Cooper Security or Scantronic i-ON Installation Guidance Notes