Alert Electrical Limited

Scantronic I-ON30EXD Includes a plug on Digicom

The Scantronic i-ON30EX is the main control unit for an expandable 10 zone hybrid, wired or wirefree burglar alarm system up to 30 zones. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD

Read More

CodeI-ON30EXD
Stock1 in stock
ReviewsNo reviews yet

Prices from: £75.95


Scantronic I-ON30EXD Includes a plug on Digicom
 Click to Enlarge
Option PriceQty. 
Scantronic I-ON30EXD Includes a plug on Digicom (I-ON30EXD)
(1 in stock)
£88.64
£106.37 inc. VAT
Less Qty.More Qty. Add to Cart
Scantronic I-ON30EX 10 Zone Expandable To 30 Zones Security System (I-ON30EX)
(4 days estimated delivery)
£75.95
£91.14 inc. VAT
Less Qty.More Qty. Add to Cart
Download Data Sheet
Brand

i-ON30EX

 

Scantronic I-ON30EX 10 Zone Expandable To 30 Zones Security System

The i-on30EX is a 10 zone control panel which expands up to 30 zones using either a wired expander EXP-W10 or a radio expander (EXP-R10). The i-on30EX has a plug on footprint which will allow the connection of any i-on communicator. The i-on30EX will support a 7Ah battery. The i-on30EX supports semi automatic addressing and the expander location system. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD please see below.

The i-on30EXD is a 10 zone control panel which expands up to 30 zones using either a wired expander EXP-W10 or a radio expander (EXP-R10). The i-on30EXD has a plug on footprint which will allow the connection of any i-on communicator as well as a built in multi-format digital communicator. The i-on30EX will support a 7Ah battery. The i-on30EXD supports semi automatic addressing and the expander location system. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD please see below.

The expandable i-on platform offers a range of clear benefits to installers these include:

  • Decimal expansion system 
  • Performance bus technology
  • Semi-automatic addressing
  • Bus device locator

Housing

A coated steel case houses the control unit’s pcb, power supply and up to two 17A backup batteries. The case is designed for vertical mounting on a wall, and provides three fixing points. The case can be butted up to side walls or a ceiling without blocking the lid. The lid is fixed by a single screw, and can be hung from the case back when open.

Zone Connections

The control unit provides connections for up to 10 wired zones. These zones can be either all Closed Circuit (CC) or all Fully Supervised Loop (FSL). The Installer can select the zone wiring type during initial commissioning, or at any time after. The Installer can make the wiring type of the expanders either CC or FSL, independently of the wiring type of zones on the control unit.

Outputs

The control unit provides connectors for four programmable outputs which can be used to control external equipment (two transistor outputs and two voltage free changeover contacts). In addition there are dedicated external bell and strobe outputs. Expanders also provide connectors for additional external sounders and outputs.

A separate set of 16 pins on the control unit pcb provide programmable outputs designed to control a separate digital communicator.

If required the Installer can connect one 16Ohm extension loudspeaker to increase the audibility of setting and unsetting tones. Each expander also provides connectors for a 16Ohm extension loudspeakers

Keypads

The i-on30EX uses i-kp01 keypads with keypad firmware version 2 and above. The keypad has a two line by 20 character backlit LCD display and a built in proximity tag (prox tag) reader. All keypads connect directly to the system bus.

Users can set and unset the system or partitions from the keypad, either by keying-in access codes or presenting a prox tag.

Expanders

The EXP-W10 wired expander provides connections for either 10 FSL zones or five CCL zones, one loudspeaker and four wired programmable outputs

The radio expanders provide channels for either 10 radio detectors (EXP-R10) or 30 radio detectors (EXP-R30). In addition each radio expander provides channels for: two radio keypads, two external radio sounders and two Wireless Accessory Modules (WAMs). Each radio expander also provides wired connections for a Loudspeaker.

Security Grade

During initial power up (and if you reset a system to factory defaults) the system provides an opportunity for you to set various system options in one step in order to program the system for either EN50131-1:2009 Grade 2. PD6662.2010 and BS8243.2010 Approval

You can override any of the settings by selecting individual options in other parts of the Installer Menu. Note that if you do so then the system may no longer comply with the Grade.

Programming the System

As an installer you can program the system in any of three separate ways:

a) From the keypad.

b) From a PC or laptop connected to the control unit via Ethernet cable, and using a web browser (IE 8 recommended).

c) From a PC or laptop connected to the control unit either over the PSTN or via the USB port, using i-on Downloader software (available soon).

Compatible Products

AB7 7ah 12v back up battery
XCELR Radio PIR
XCELRPT Pet tolerant Radio PIR
XCELW Hard wired PIR
XCELWPT Pet tolerant wired PIR
EXP-W10 Wired 10 zone expander , utilises the new i-on bus system
EXP-R10 Radio 10 zone expander, utilises the new i-on bus system
EXP-R30 Radio 30 zone expander, utilises the new i-on bus system
i-RC01 4 relay board converts transistorised output to relays.
I-KP01 Wired keypad for the i-ON range.  Up to two can be installed on the Scantronic i-ON16. Includes prox reader and two button panic attack
I-RK01 Radio keypad for the i-ON range.  Up to two can be installed on the Scantronic i-ON16. Includes prox reader and two button panic attack
I-SD02 Plug-in SD/comms module.  Connect to central station or send voice messages to phone numbers of your choice
I-GSM02 GSM autodialler

I-DIG02

Telephone auto-dialler for the i-ON40 and i-ON160EX control units
I-FB01 Remote control for the i-ON16.  Allows setting, part-set and un-set.
760ES External radio sounder complete with cover.  Designed specifically for the i-ON range.
760DS Dummy sounder complete with cover.
710rEUR-00 Radio small profile hand held dual action PA transmitter.
720rEUR-00 Optical smoke detector.  Uses 9v battery
734rEUR-01 Lithium powered White contact TX
734rEUR-06 Lithium powered Brown contact TX
738rEUR-00 White Spyder shock/vibration sensor
738rEUR-04 Brown Spyder shock/vibration sensor
770REUR-00 Wireless Accessory Module WAM
771REUR-00 Wireless Information Module

 

Please click this link for Scantronic user manuals 

For further information on the Scantronic i-ON wireless burglar alarm equipment please see Scantronic i-ON range from Cooper Security or Scantronic i-ON Installation Guidance Notes

Submit a Review

Scantronic I-ON30EX 10 Zone Expandable To 30 Zones Security System Scantronic I-ON30EX 10 Zone Expandable To 30 Zones Security System
0 0
The Scantronic i-ON30EX is the main control unit for an expandable 10 zone hybrid, wired or wirefree burglar alarm system up to 30 zones. SUPPLIED PANEL ONLY - REQUIRES AN i-on KEYPAD

Product Categories

Alarms & CCTV

Next Day Delivery

All enquiries please contact via live chat 9am - 4pm Monday to Friday support@support.alertelectrical.com please include your order number (Starts W201..)

© Copyright 2012 Alert Electrical Limited. Unit 2/3 Clarendon Court | Manners Industrial Estate | Ilkeston | Derbyshire | DE7 8EFTop